user login

7.5t/h Waste Heat Boiler

Min. Order: 1 Set/Sets
Trade Term: FOB
Payment Terms: L/C, T/T
Supply Ability: 100 Set/Sets per Year
Place of Origin: Henan

Company Profile

Location: Zhengzhou, Henan, China (Mainland)
Business Type: Manufacturer, Trading Company, Agent, Distributor/Wholesaler, Service, Association, Other
Main Products: Waste Heat Boiler, Carbon Kiln Waste Heat Boiler, Boilers, Glass Kiln Waste Heat Boiler, Boiler

Product Detail

Model No.: QC Series
Means of Transport: Ocean
Fuel: waste heat
Output: 7.5t/h
Usage: industry
Structure: water tube
Pressure: low pressure
Style: vertical
Type: natural circulation
Production Capacity: 100 Set/Sets per Year
Packing: standard export package
Delivery Date: four months
Show

Product Description

 Features of 7.5t/h Waste Heat Boiler is:
1.energy-saving to achieve thermal energy utilization. Waste Heat Boiler is to use micro-dust concentration in flue gas remaining heat of waste recycling systems can be used for power generation, production, life of superheated steam.It does not use disposable fuel, so it has the characteristics of energy-saving and comprehensive utilization of energy.
2.furnace dust. it is conducive to environmental protection.
Due to the flue gas contains large amounts of coarse dust, the boiler uses combined inertia separation principle and gravitational separation principle to achieve separation of dust, reducing soot content.
3. low resistance, running economy.
Waste Heat Boiler heating surface by adjusting the flow rate of flue gas flow cross-sectional area to achieve the design, reducing the bulk resistance, conducive to the integration with other devices and reduce system power consumption.
4. compact.it looks neat in appearance.

Basic characteristics of 7.5t/h Waste Heat Boiler
1.boiler specification
rated evaporation                 7.5t/h
rated steam temperature             204.3℃  
rated steam pressure                  1.6MPa
feed water temperature                 104℃
exhaust gas temperature               550℃
import of boiler flue gas                 20350Nm3/h
import of boiler flue gas temperature    1130℃
import of boiler flue gas dust content    2.5g/Nm3
2.flue gas content(%):  
(1) CO2      8.38
(2) H2O      10.73
(3) O2        8.98
(4) N2        71.91
(5)HCL       <900mg/ Nm3
(6)SO2       <1500mg/ Nm3
3.boiler basic dimensions
boiler width (centerline distance of about two left and right columns)       6000mm
boiler depth(centerline distance of about two front and back columns)                  16830mm
drum elevation       21350mm

Design features of 7.5t/h Waste Heat Boiler  
7.5t/h Waste Heat Boiler is verticalnatural circulation. The heat from the boiler is flue gas which is discharged from hazardous waste incineration. Boiler feed water temperature is 104 ℃.Working fluid directly into the drum, and then from the drumdown pipe flows through the membrane wall, where after being heated steam conduit reintroduction drum, and then separated by soda leads to saturated steam from the steam drum.
7.5t/h Waste Heat Boiler heating surface adopts membrane wall structure, the pipe diameter is Φ60. Membrane wall is left on the hole, blowing holes . the user adopts sootblowers according to specific circumstances. Boiler furnace wall select light furnace wall.

Structure introduction of 7.5t/h Waste Heat Boiler
1.Drum
Drum diameter isФ1500.Material of drum is 20g.The main equipment in the boiler is underwater plate,corrugated plate separator,feed water system and so on. Soda mixture come into the drum, first by underwater plate, and then further separation by the corrugated plate separator, after that it lead out.
2. Evaporating heating surface is composed by the inlet and outlet header and the membrane wall.The header is made ofФ219 steel tube. The membrane wall is made ofФ60 tube and welded steel.
3.boiler pipes
The boiler drum installs safety valve, pressure gauge,water table, continuous blowdown, dosing valve and so on.
4.furnace wall
This boiler adopts light furnace wall.So as to improve boiler effiency,reduce furnace wall leakage,reduce heat loss from the boiler.The drum insulation thickness is about 100-120mm. All leads, down tube and pipe insulation thickness is 80mm.The material is calcium silicate insulation coating.
5. water quality and export steam quality requirements.
Boiler feed water and boiler water indicators should be consistent GB1576-2001.
Post Buying Request