Min. Order: | 50 Piece/Pieces |
---|---|
Payment Terms: | T/T |
Supply Ability: | 10000 Unit/Units per Month |
Place of Origin: | Zhejiang |
Location: | Ningbo, Zhejiang, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company, Agent, Distributor/Wholesaler |
Model No.: | NT15-P |
---|---|
Means of Transport: | Ocean |
Theory: | Current Sensor |
Usage: | Magnetic Sensor |
Brand Name: | CSR |
Output: | Current |
Primary nominal: | 15Arms |
Production Capacity: | 10000 Unit/Units per Month |
Packing: | up to customer |
Delivery Date: | 4 weeks upon receipt of confirmed order |
UPS hall sensor
High accuracy Good linearity
Low thermal drift
Good current overload capability
Conform to UL94-V0 standard
UPS hall sensor
Application
For the electronic measurement of currents: AC, DC IMPL.,etc.,with galvanic isolation between the primary (high power) and the secondary (electronic) circuits.
Electrical data:
1. Normal current IPN: 15A rms
2. Measuring range IP: 0~+/-48A
3. Number of secondary turn: 2000
4. Load resistance RL: not less than 2000 ohm
5. Supply voltage (+/-5%): +5V
6. Current consumption( at +5V): 28+Is+(Vout/ RL) mA
7. Isolation: Between primary and secondary: 3kV rms/50Hz/1min
Accuracy – Dynamic performance data:
1. Accuracy X @IPN ,TA=+25ºC +/-0.7%
2. Non-linearity: +/-0.1%(+25ºC)
3.Offset of zero current: 2.5V±0.025V(+25ºC)
4. Thermal drift: @-40ºC~+85ºC:≤300ppm/ºC
5. Response time ≤400ns
8. di/dt accurately followed: ≥35A/us
General data:
1. Operating temperature: -40ºC~+85ºC
2. Storage temperature: -40ºC~+100ºC
3. Weight: 10g
4. Standards: EN50178:1997
Features:
1. Zero magnetic flux Hall effect principle
2. Single-circuit power supply
3. Insulated plastic case made of white PPO recognized according to UL 94-V0
4. The whole current transducer comply with RoHS Directive completely
15A UPS Hall Current Transducer
15A UPS Hall Current Transducer Connection:
15A UPS Hall Current Transducer Dimension: