Applications:
For the electronic measurement of currents: AC, DC IMPL.,etc.,with galvanic
primary (high power) and the secondary (electronic) circuits.
Main technical data:
1. Primary normal current IPN: 50A r.m.s
2. Primary current, measuring range IP: 0~+/-70A
3. Measuring resistance: RMmin RMmax
with +/-12V @ +/-50A max: 0 ohm 140 ohm
@ +/-70A max : 0 ohm 70 ohm
with +/-15V @ +/-50A max: 0 ohm 200 ohm
@ +/-70A max: 0 ohm 110 ohm
4. Secondary normal current: 50mA rms
5. Conversion ratio: 1:1000
6. Supply voltage (+/-5%): +/-12V~+/-15V
7. Current consumption: 20±5mA (@+/-15V)+ Secondary output current
8. Isolation test: Between the primary circuit and the secondary circuit(+.-.M): 6kV
Accuracy – Dynamic performance data:
o
1. Accuracy @ IPN, TA=+25 C: +/-0.8%
2. Non-linearity: ≤±0.1%
o
3. Offset current: not more than +/-0.2mA(@+25 C)
o o
4. Thermal drift: ≤+/-0.60mA(-25 C ~+85 C)
5. Response time @90% of IPN: not more than 1us
6. dI/dt accurately followed: better than 100A/us
General data:
1. Operating temperature: -45oC~+85oC
o o
2. Storage temperature: -45 C ~+90 C
3. Secondary coil resistance: not more than 11 ohm
4. Weight: ≤100g
5. Standards: EN 50155
Features:
1. Hall effect measuring principle
2. Galvanic isolation between primary and secondary circuit
3. Insulated plastic case made of white PPO recognized according to UL 94-V0
Dimension:
Connection: