user login

2-Wire Conventional Photoelectronic Smoke Detector

Min. Order: 1000 PCS
Payment Terms: L/C, T/T
Supply Ability: 5000000 Pieces per Year
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: LED Remote Indicator Sensitive Conventional Flame Detector, 9VDC Block SND-500-S Smoke Alarm, 2-wire Intelligent Addressable Smoke Detector, 2-Wire 60 UA Photoelectronic Smoke Detector, 2 Wire LED Remote Indicator Conventional Heat Detector

Product Detail

Model No.: SNC-300-S2
Means of Transport: Ocean, Air
Wiring:: 2 wire
Power supply:: 10.8 to 33 V DC
Quiescent current:: 60 uA
Alarm current: 50 mA
Temperature:: -10℃ to +55℃
DETECTOR CLASS: Photoelectronic
APPROVAL: UL; CE; EN54
SUPPLYVOLTAGE: 10.8 to 33V DC
QUIESCENT CURRENT: 60μA @24V
ALARM CURRENT: 50mA@24V
Production Capacity: 5000000 Pieces per Year
Packing: 1PC one box; 100PCS/CTN
Delivery Date: 30DAY
Show

Product Description

 product name 2-Wire Conventional PhotoelectronicSmoke Detector
2-Wire Conventional PhotoelectronicSmoke Detector
Model SNC-300-S2 smoke detector uses a specialized smoke chamber design, which could sense the presence of smoke particles produced by fast combustion or slow smoldering fire.

The detector will work well with most modern fire alarm control panels, and meets the requirements of UL 268 and EN 54-7/5.

Description:  
Series SNC-300 smoke detector incorporates well proven sensing technologies, together with advances in materials and electronics technology, and represents the pinnacle of fire detector performance and reliability.
Series SNC-300 smoke detector has an extra aureola to improve detector identification in an alarm condition, so polished and advanced design allow an alarm to be observed from all angles.
The detector will work with most modern fire alarm control panels, and meets the requirements of UL 268 and EN 54-7/5.  
Feature:
1) 2-Wire operation
2) Wide operating voltage
3) Advanced electronic technology
4) Proven detection performance
5) Designed to meet approvals worldwide
6) Certificated by UL,BSI, CE;
MODEL
SNC-300-S2
DETECTOR CLASS
Photoelectronic
SUPPLY WIRING
2 – Wire
DESIGN STANDARD
EN 54-7 and UL 268
APPROVAL
UL; CE; EN54
SUPPLYVOLTAGE
10.8 to 33V DC
QUIESCENT CURRENT
60μA @24V
ALARM CURRENT
50mA@24V
TEMPERATURE RANGE
-10℃ to +55℃
HUMIDITY
0% to 95% RH No Condensation
SENSITIVITY
UL:2.3%FT; EN 54:0.15dB/m
IP RATING
IP 43
CIRCLE TIME
3-5 Seconds
DIMENSIONS (dia. x height)
102 x 45mm (with Base)
WEIGHTS
130g(with Base)

picture of 2-Wire Conventional PhotoelectronicSmoke Detector
2-Wire Conventional PhotoelectronicSmoke Detector

2-Wire Conventional PhotoelectronicSmoke Detector
Post Buying Request