NACL.1000-S1/SP1 Current Transducer

Min. Order: 500 Piece/Pieces
Payment Terms: T/T
Supply Ability: 10000 Unit/Units per Month
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company, Agent, Distributor/Wholesaler

Product Detail

Model No.: NT1005-S/SP1
Means of Transport: Ocean
Theory: Current Sensor
Usage: Magnetic Sensor
Brand Name: CSR
Output: Current
Primary nominal: 1000Arms
Production Capacity: 10000 Unit/Units per Month
Packing: up to customer
Delivery Date: 4 weeks upon receipt of confirmed order
Show

Product Description

For the electronic measurement of currents: AC, DC IMPL.,etc.,with galvanic isolation between the primary (high power) and the secondary (electronic) circuits.

Main technical data:

1. Primary normal current IPN: 1000A r.m.s                               

2. Primary current, measuring range IP: 0~±2000A

3. Secondary normal current:200mA rms

4. Conversion ratio: 1:5000

5. Supply voltage(1±10%): ±15V~±24V      

1.       @±1000A max 0Ω~15Ω ±15V

           @±1200A max 0Ω~4Ω   ±15V

           @±1000A max 0Ω~50Ω ±24V

           @±1200A max 0Ω~5Ω   ±24V






6. Current consumption: ≤35mA(+ Secondary output current

7. Isolation test: Between the primary circuit to the secondary circuit(+.-.M): 7kVrms/50Hz/1min

Accuracy – Dynamic performance data:

1. Accuracy @ IPN, TA=+25 oC,  ≤±0.4%

2. Non-linearity: better than 0.1%, TA=+25 oC

3. Offset current @ IP=0, TA=+25 oC: not more than ±0.4mA

4. Thermal drift: ±0.8mA(-40 oC ~-85 oC)
                              ±0.7mA(-25 oC+70oC)  

5. Reaction time @10% of IP max : less than 500ns

6. Response time @90% of IPN: not more than 1us

General data:

1. Operating temperature: -40℃~+85℃
2. Storage temperature: -40℃~+90℃
3. Secondary coil resistance: not more than 45Ω(@+25℃)
4. Weight:

                1.02kg

                  1.68kg

5. Standards: EN 50155

Features:

1. Hall effect measuring principle

2. Galvanic isolation between primary and secondary circuit

3. Insulated plastic case made of black PC recognized according to UL 94-V0

4. The whole current transducer comply with RoHS Directive completely

1000A Excavator transducer Dimension:


1000A Excavator transducer Connection: