user login

S Type Load Cell

Place of Origin: Zhejiang

Company Profile

Location: Hangzhou, Zhejiang, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: 635A

Product Description

  635A Load Cell, 50kg...10,000kg
Special features :  
● Equivalent to OIML R60 C3 (Emax≥300kg)
     regulations up to 5 000d for scales class lll
● Suitable for use under conditions of tension and
     compression
● Protection to IP66/IP67
● Compatible with other sources
● Explosion proof version (Ex ib II CT4)
● Available Options:
   -Service temperature range up to 120℃ [248℉]
   -6-wire ciruit
   -Stainless steel
Dimensions (in mm; 1mm = 0.03937 inches)

 
Technical Data
Type 635A
Accuracy class according to OIML R60
Maximal numbers of load cell verification intervals  (nLC)  
 -
 5 000
 C3
 5 000
Maximal capacity (Emax)


Weight (G), approx.
 kg

 
 kg
 50;100;


 1.3
 300;500;1,000;
 SE-2,000
 
 0.8
2,000;
3,000;
5,000
1.5
10,000


 7.5
Minimum load cell verification interval (Vmin)
Sensitivity (Cn)
Zero balance
Temperature effect on sensitivity (TKc) *
Temperature effect on zero balance (TKo)
Non-linearity (dlin)  *
Repeatability (drep) *
Hysteresis error (dhy)  *
Creep (dDR)in 30 min.
Input resistance (RLC)〔Red(+)-black(-)〕
Output resistance (Ro) 〔Green(+)-while(-)〕
Reference excitation voltage (Uref)
Maximal excitation voltage
Insulation resistance (Ris)
Nominal temperature range
Service temperature range
Storage temperature range
% of Cn
mV/V
mV/V
% of Cn/k
% of Cn/k
%
%
%
%
Ω
Ω
V(DC/AC)
V(DC/AC)

℃[oF]
oF]
oF]
0.02
2±1%
±0.04
< ±0.0012
<±0.0040
<±0.017
<±0.017
< ±0.017
< ±0.023
400 ±25
350±3
0.5…12
18
>2[50 VDC ]
-10…+40[15…+105]
-25…+70[-15…+160]
-50…+85[-60…+185]
Safe load limit (EL)
Breaking load (Ed)
% of Cn
% of Cn
  150
  300
Protection class (IP) acc. to IEC529
  IP66/IP67
Material
  Steel alloy
Optionally
  Explosion proof version(Ex ib II CT4)
* The data for deviation of linearity, repeatability, hysteresis error and temperature effect on sensitivity are typical values. The sum of these data meets the requirements according to OIML R60.
Post Buying Request