user login

Emerson Turbidity Meter Sensor

12000.0 RMB
Min. Order: 1 Piece/Pieces
Trade Term: EXW
Payment Terms: T/T
Supply Ability: 1000
Place of Origin: Hubei

Company Profile

Location: Wuhan, Hubei, China (Mainland)
Business Type: Trading Company

Product Detail

Model No.: 8-0108-0002-EPA
Production Capacity: 1000
Packing: 1
Delivery Date: 20-30 work days
Show

Product Description

8-0108-0002-EPA Emerson Turbidity Meter Sensor

1,T1056 Emerson turbidity meter

The Clarity II complete turbidity analysis system includes: 1 single / dual channel analyzer, 1 / 2 sensors and bubble removal detection tank, dedicated

cable. Cables connect sensors and analytical instruments up to 50 feet (15.2 meters).

The analyzer of the Clarity II Turbidity Analysis System is a universal, easy-to-use 1056 analyzer from Rosemount Analytical.

The number is in large font LCD display, the instrument's operation menu is concise and intuitive, and the clear language prompt helps the user without the operation manual.

The entire operation can be completed. The instrument has two 4-20mA analog outputs and four relay alarm outputs. The alarms can be defined as high or low.

Or dead zone alarm. For ease of programming, the T1056 Turbidity Analyzer automatically recognizes that the sensor it is connected to meets US EPA 180.1 environmental standards.

Still meet international ISO 7027 environmental standards

The Clarity II Turbidity Analyzer is used to monitor the turbidity of aqueous solutions with low scattering light, high stability, effective elimination of bubbles and high display resolution.

Features such as (0.001 NTU) are ideal for monitoring turbidity in drinking water. Since the Clarity II Turbidity Analyzer can measure up to 200 NTU,

So it can also monitor the turbidity of most raw water. In summary, the Clarity II Turbidity Analyzer can be used for drinking water treatment, sewage treatment outlets, and cold

Condensate recovery and monitoring of turbidity water turbidity.

The Clarity II Turbidity Analyzer is available in two environmentally-friendly sensors, one that meets US EPA 180.1 environmental standards and one that meets the requirements of the United States.

ISO 7027 environmental standards. The former uses a visible light source and the latter uses a near-infrared light-emitting diode. In the United States, choose to meet EPA 180.1

Environmentally-friendly sensors; in other countries, appropriate sensors can be selected according to the environmental regulations of their respective countries.



2.T1056 Rosemount Turbidimeter Spare Parts

Part number Description

23554-00 cable gland, 5 pcs/pack

23820-00 Analyzer short tube mounting accessories, including: U-bolts, mounting brackets, nuts, washers, screws

24101-00 calibration cup

24138-00 sensor cable, turbidity analysis, 3 feet

8-0108-0002-EPA Replaceable Sensors in Accordance with US EPA Standards

8-0108-0003-ISO Replaceable sensor in accordance with international ISO standards

24103-00 Rotameter with adjustable flow

9240048-00 stainless steel nameplate

9550145 Sensor with O-rings connected to the bubble detection flow cell

24170-00 Except bubble detection flow cell

9550322 Upper and lower O-rings except for the bubble cup

1-0901-0009-EPA Replaceable Bulbs for EPA Standards

1-0901-0010-ISO Replaceable Lamps in Accordance with International ISO Standards


Post Buying Request