customized anti-DC component current transformers

Min. Order: 1 Piece/Pieces
Trade Term: FOB,CFR,CIF,FAS,CIP,CPT,FCA,EXW
Payment Terms: Paypal, L/C, D/P, D/A, T/T, WU, Money Gram
Place of Origin: Zhejiang

Company Profile

Location: Jiaxing, Zhejiang, China (Mainland)
Business Type: Manufacturer
Main Products: Current Transformer, Transformer, Common Mode Inductor, Magnetic Core

Product Detail

Means of Transport: Ocean, Air
customization: RoHs compliant
Packing: can be customized

Product Description

CTD series are Anti-DC component current transformers, they can detect the DC component of the current,the precision grade is 0.1 class,they are widely used in grid electricity measurement meters and intelligent power system;

CTD series

error range:

accuracy class

Current ratio error(%)

 phase error±'

Rated current percentage value

Rated current percentage value

5

20

100

Imax

5

20

100

Imax

0.1

≤0.1

≤0.1

≤0.1

≤0.1

≤12

≤10

≤5

≤5

The error value of DC component resistance ratio(%)

≤±2.8

Selection of reference

Model

Rated Pr.Curren In(A)

Max.Current Imax(A)

Rated Sec.Current (mA)

accuracy

LR(Ω)

CTG2mA/2mA0.1S15Ω

2

---

2

0.1

15

CTG5(60)A/2.5mA0.1S15Ω

5

60

2.5

0.1

15

CTG5(80)A/2mA0.1S15Ω

5

80

2

0.1

15

CTG5(100)A/2.5mA0.1S15Ω

5

100

2.5

0.1

15

CTG10(150)A/2.5mA0.1S15Ω

10

150

5

0.1

15

We can make customized dimension and specification.