Product Detail

Model No.: HYVA-404
Means of Transport: Ocean, Air
Brand Name: Huaying
Production Capacity: 100 sets
Packing: wooden case
Delivery Date: 7 working days
Show

Product Description

Product introduction:
1 Tests for Current Transformer:
1Excitation curve and parameters test 





2Turns ratio test 





3Ratio and phase error test 





4Polarity mark check 





5Winding resistance measurement 





6Secondary loop burden measurement 





7Error line curve test for protection CT 





8Transient CT parameters test 





9CT nameplate guess 





10Saturation hysteresis loop curve measurement





1 Tests for potential transformer
1Turns ratio test 





2Ratio error and phase angle error test 





3Polarity test 





4Secondary burden test 





5Winding resistance test





Product technical index:
1Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13 





2Power supply: AC220V±10%, 50/60Hz±10% 





3Voltage output: 0.1~180V (AC) 





4Current output: 0.001~5A(RMS) 





5Power output: 500VA 





6Maximum knee voltage measurement: 45KV 





7Current measurement: 






Range: 0~10A (automatically change range in 0.1/0.4/2/10A)  






Error: <±0.1%+0.01%FS 





8Voltage measurement: 






Range: 0~200V (automatically change range in 1V/10V/70V/200V) 






Error: < ±0.1%+0.01%FS 





9Turns ratio measurement: 






Range:1~35000 






1~2000          error<0.05% 






2000~5000    error<0.1% 






5000~35000  error<0.2% 





10Phase measurement: error: ±2min; resolution: 0.01min 





11Winding resistance measurement:  






Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) 






Error: < 0.2%RDG+0.02%FS 






Maximum resolution: 0.1mΩ 





12Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree 





13CT Secondary burden: 






Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) 






Error: <0.2%RDG+0.02%FS  






Maximum resolution: 0.001ohm 





14PT Secondary burden: 






Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) 






Error :<0.2%RDG+0.02%FS  






Maximum resolution: 0.1ohm 





15PT ratio measurement: 






Range: 1~35000 






1~10000 error<0.1% 






10000~35000 error<0.2% 





16PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1% 





17PT phase angle measurement: maximum error < 3min 





18Make evaluation for test results according to selected standards 





19Make word report for test result 





20Make word reports one time for multi-group test records on the PC 





21Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test 





22Compare excitation curves with saved excitation curves in the same window 





23Memory capacity: >1000 groups test results  





24Working condition: temperature: -10℃~50℃; moist: ≤90% 





25Size: 485mm×356mm×183mm 





26Weight: <15kg





Product tags:
ct pt analyzer, current transformer analyzer, ct analyzer, pt analyzer, ct tester, pt tester
current transformer testing equipment, current transformer manufacturer, current transformer maker,
hyva-404 series maker, electrical test equipment, hv test equipment.
Product contact manager:
Name: Chloe Shuyue Wang
Email:  whhy818@163.com
Skype: wangshuyue1991

Post Buying Request