Description of Rice Bean Oil Extraction unitmachinery :
It is a modern and one of the most advanced oil extraction equipment thatfixed grid of stainless steel plate extractor. Retained its low powerconsumption, reliable operation of equipment , long life ,easy maintenance, goodbenefits leaching effect compared with traditional false bottom andextractor.
Daily treatment :30T, 50T, 80T,100T,150T, 200T, 300T, 450T, 600T,800T...3000TAs your requirement
Production Process of Rice Bean Oil Extraction unitmachinery
(1) The material (for pretreatment) is sent to rotary extraction by thescraper conveyor. The material will extracted by the solvent or mix oil. Afterthis step, we will get meal and mix oil.
(2) Meal is sent to toaster. Through the toaster, the solvent in the mealwill separate from the meal. The solvent goes to condenser and is recycled torotary extraction.
(3) After the mix oil from the rotary extraction enters into 1st evaporatorand 2nd evaporator, most of the solvent in the mix oil is separated.
(4) The mix oil from 2nd evaporator goes to stripping tower and almost allthe solvent is separated. From the stripping tower, we can get crude oil andsolvent. The solvent is sent to condenser and is recycled to rotaryextraction.
Advantage of Rice Bean Oil Extraction unitmachinery
Solvent pumps | continuously spray solvent to the rotary-typeextractor |
Roary extractor | Spray and soak the pre-pressed cake with solvent so that oil fatscan be dissolved in solvent(form miscella). After processing, you can get wetmeal and miscella (mixed oil). |
DTDC | usd to separate the solvent from the wet meal. |
Miscella tank 1st | pump the miscella (oil with solvent) in to the miscella 1st , and then add10% saline water to it. The phospholipid and impurities in the miscella willreact with the saline wter, at last the reactant precipitate, reaching the goalof purifying. |
Miscella tank 2nd | the purified miscella will be pumped into it |
Miscella stripping | it will remove the remaining solvent in miscella. And the solventwill be discharged to condenser for recycling. |
condensers | used to cooling the solvent gas separated from the wet meal andmiscella for recycling. |
(1) Energy & labor saving; high oil yield rate ;
(2) 1.5% low residual oil rate of meal ; good quality meal
(3) Low solvent consumption, high solvent recovery
(4) Low processing cost , high labor productivity