DC pressure level transmitter 4-20mA
Specification:
Range:0-600bar,
Connection:G1/2,G1/4,M20x1.5, M14,M12,M10,etc.
Tolerance:+/-0.5%Fs,
Output:4-20mA,0-10V,0-5V,1-10V,1-5V.
Electrical connecion: terminal box, or circular connector M12x1.
Brief description:
This pressure transmitter can be used for measuring the relative (
gauge) and absolute pressures in liquids and gases. The
pressure transmitter operates on the piezoresistive measuring principle. The pressure is converted into an electrical signal.
Technical data:
Reference conditions to DIN 16 086 and IEC 770/5.3
Measurement ranges,see Order details
Overload limit,for ranges up to 0 — 25 bar 3 x full scale
Bursting pressure,for ranges up to 0 — 25 bar ≤ 4 x full scale
Parts in contact with medium standard: stainless steel, Mat. Ref. 1.4571,1.4435
Output:4 — 20 mA
2-wire burden ≤ (UB-10 V) / 0.02A
0.5 — 4.5 V burden ≥ 20 kΩ
1 — (5)6 V burden ≥ 10 kΩ
0 — 10 V burden ≥ 10 kΩ
Burden error,< 0.5% max.
Zero signal deviation≤ 0.3% of full scale
Thermal hysteresis≤ ± 0.5% of full scale
(within compensated temperature range)
≤ ± 1% for ranges 0 — 250 mbar
0 — 400 mbar
0 — 600 mbar
Ambient temperature error within range -20 to +85°C
(compensated temperature range)
zero: ≤ 0.02%/°C typical,
≤ 0.04%/°C max.
span: ≤ 0.02%/°C typical,
≤ 0.04%/°C max.
Deviation from characteristic
≤ 0.5% of full scale(limit point adjustment)
Hysteresis
≤ 0.1% of full scale
Repeatability≤ 0.05% of full scale
Response time≤ 3 msec max.
Stability over 1 year≤ 1% of full
scale
Supply:10 — 30 V DC (for output 4 — 20 mA
and 1 — (5)6 V),5 V DC (for output 0.5 — 4.5 V)
11.5 — 30 V DC (for output 0 — 10 V)
Ripple: the voltage spikes must not go outside the limits specified for the supply.
Max. current drawn: approx. 25 mA
Supply voltage error:≤ 0.02% per V
(nominal supply voltage 24 V DC)
ratiometric with supply 5 V DC (±0.5 V)
Permissible ambient temperature
for version with connector:-20 to +125°C
for version with attached cable:-20 to +100°C
Storage temperature:-40 to +125°C
for version with attached cable:-20 to +100°C
Permissible temperature of medium:-30 to +125°C
Electromagnetic compatibility (EMC),to EN 61 326
Mechanical shock (to IEC 68-2-27) 100 g/1 msec
Mechanical vibration (to IEC 68-2-6) 20 g max. at 15 — 2000 Hz