user login

EN 54 & UL Certificated Optical Smoke Detector

5.0~12.0 USD
Min. Order: 1000 Piece/Pieces
Trade Term: FOB
Payment Terms: L/C, T/T, WU
Supply Ability: 5000000PCS/YEAR
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: LED Remote Indicator Sensitive Conventional Flame Detector, 9VDC Block SND-500-S Smoke Alarm, 2-wire Intelligent Addressable Smoke Detector, 2-Wire 60 UA Photoelectronic Smoke Detector, 2 Wire LED Remote Indicator Conventional Heat Detector

Product Detail

Model No.: SNC-300-S2
Means of Transport: Air, Land
Brand Name: NUMENS
DETECT CLASS: EN 54 & UL Certificated Optical Smoke Detector
WIRING SUPPLY: 2 / 4 -Wire Polarity Insensitive
QUIESCENT CURRENT: 60uA
ALARM CURRENT: 50mA
POWER SUPPLY: 10.8V to 33VDC
TEMPERATURE: -10℃ to +55℃
SENSITIVITY: UL:2.3%FT; EN 54:0.15dB/m 57℃, AIR
HUMIDITY: 0% to 95% RH No Condensation
APPROVAL: EN:0086-CPD-587752 ; UL:S25212
IP RANG: IP 43
Production Capacity: 5000000PCS/YEAR
Packing: 1pc/box, 100pcs/ctn, Or package as customer's request
Delivery Date: 20 to 35days
Show

Product Description

 EN 54 & UL Certificated OpticalSmoke Detector

Series SNC-300 smoke detector incorporateswell proven sensing technologies, together with advances in materials andelectronics technology, and represents the pinnacle of fire detector performanceand reliability.
Series SNC-300 smoke detector has an extraaureola to improve detector identification in an alarm condition, so polishedand advanced design allow an alarm to be observed from all angles.
The detector will work with most modern firealarm control panels, and meets the requirements of UL 268 and EN54-7/5.
EN 54 & UL Certificated Optical Smoke Detector
Features:
1)Easy installation and maintenance;
2)Durable sensor head, no need for replacement;
3)Advanced detection and discrimination algorithms;
4)Sleek and professional housing design;
5)Certificated by UL,BSI, CE;
Specification:
MODEL
SNC-300
DETECTOR CLASS
Optical Smoke
SUPPLY WIRING
2 / 4 – Wire polarity Insensitive
DESIGN STANDARD
EN 54-7 and UL 268
APPROVAL
CE and UL
SUPPLYVOLTAGE
10.8to 33V DC
QUIESCENT CURRENT
60μA @24V
ALARM CURRENT
50mA@24V
TEMPERATURE RANGE
-10°C to +55°C
HUMIDITY
0% to 95% RH No Condensation
SENSITIVITY
UL:2.3%FT; EN 54:0.15dB/m
IP RATING
IP 43
START-UP TIME
10 Seconds
DIMENSIONS (dia. x height)
102 x 45mm (with Base)
WEIGHTS
130g (with Base)
EN 54 & UL Certificated Optical Smoke Detector
Model:
SNC-300-S22-WireConventional Optical Smoke Detector
SNC-300-SL 2-Wire OpticalSmoke Detector with Remote Indicator
SNC-300-C22-Wire CombinedOptical Smoke and Heat Detector
SNC-300-CL2-Wire CombinedSmoke and Heat Detector with Remote Indicator
SNC-300-SR 4-Wire OpticalSmoke Detector with Internal Relay Output Function
SNC-300-CR 4-Wire CombinedSmoke and Heat Detector with Relay Output Function
SNC-300-SP 4-Wire SmokeDetector with External Relay Output Function (One Set)
SNC-300-SB4-Wire Smoke Detector with External Relay Output Function (DoubleSet)
EN 54 & UL Certificated Optical Smoke Detector
Post Buying Request