Model No.: SNC-300-SL
Means of Transport: Air, Land
Brand Name: NUMENS
DETECT CLASS: EN 54 & UL Certificated Optical Smoke Detector with Remote Indicator
WIRING SUPPLY: 2 -Wire Polarity Insensitive
QUIESCENT CURRENT: 60uA
ALARM CURRENT: 50mA
POWER SUPPLY: 10.8V to 33VDC
TEMPERATURE: -10℃ to +55℃
SENSITIVITY: UL:2.3%FT; EN 54:0.15dB/m 57℃, AIR
HUMIDITY: 0% to 95% RH No Condensation
APPROVAL: EN:0086-CPD-587752 ; UL:S25212
IP RANG: IP 43
Production Capacity: 5000000PCS/YEAR
Packing: 1pc/box, 100pcs/ctn, Or package as customer's request
Delivery Date: 20 to 35days
Show

Product Description

 EN 54& UL Certificated Optical Smoke Detector with RemoteIndicator

Model SNC-300-SL smoke detector uses a specialized smoke chamber design, which could
sense the presence of smoke particles produced by fast combustion or slow smoldering fire.
The detector may work with most modern fire alarm control panels, and can be installed with the
series 65 of Apollo together,also the series NB 338 of WIZMART and the FEOE 2000 of ZETA etc.
EN 54 & UL Certificated Optical Smoke Detector with Remote Indicator
Features:

1) 2-Wire operation
2) Wide operating voltage
3) Advanced electronic technology
4) Proven detection performance
5) Designed to meet approvals worldwide (e.g. UL LPCB CE)
6) Sensor base: optional installation mode. (e.g. Apollo or Wizmart's wiring mode)

Features:
1)Easy installation and maintenance;
2)Durable sensor head, no need for replacement;
3)Advanced detection and discrimination algorithms;
4)Sleek and professional housing design;
5)Certificated by UL,BSI, CE;
Specification:
MODEL
SNC-300-S2
DETECTOR CLASS
Optical Smoke
SUPPLY WIRING
2 – Wire  Polarity Insensitive
DESIGN STANDARD
EN 54-7 and UL 268
APPROVAL
CE; UL
SUPPLYVOLTAGE
10.8V to 33V DC
QUIESCENT CURRENT
60μA @24V
ALARM CURRENT
50mA@24V
TEMPERATURE RANGE
-10°C to +55°C
HUMIDITY
0% to 95% RH No Condensation
SENSITIVITY
UL:2.3%FT; EN 54:0.15dB/m
IP RATING
IP 43
START-UP TIME
10 Seconds
DIMENSIONS (dia. x height)
102 x 45mm (with Base)
WEIGHTS
130g (with Base)