user login

Conventional 2-wire photoelectric smoke detector

1.0~5.0 USD
Min. Order: 1000 PCS
Payment Terms: L/C, T/T
Supply Ability: 5000000 Pieces per Year
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: LED Remote Indicator Sensitive Conventional Flame Detector, 9VDC Block SND-500-S Smoke Alarm, 2-wire Intelligent Addressable Smoke Detector, 2-Wire 60 UA Photoelectronic Smoke Detector, 2 Wire LED Remote Indicator Conventional Heat Detector

Product Detail

Model No.: SNC-100-S2
Means of Transport: Ocean, Air
Usage: Smoke
Brand Name: Numens
Wiring:: 2 wire
Power supply:: 10.8 to 33 V DC
Quiescent current:: 60 uA
Alarm current: 50 mA
Temperature:: -10℃ to +55℃
DETECTOR CLASS: Photoelectronic
APPROVAL: CE
SUPPLYVOLTAGE: 10.8 to 33V DC
QUIESCENT CURRENT: 60μA @24V
ALARM CURRENT: 50mA@24V
Production Capacity: 5000000 Pieces per Year
Packing: 1PC one box; 100PCS/CTN
Delivery Date: 30DAYS
Show

Product Description

Product name:
Conventional 2-wire photoelectric smoke detector
Conventional 2-wire photoelectric smoke detector
Conventional 2-wire photoelectric smoke detector
SNC-100-S2 smoke detector uses a specialized smoke chamber design, which could sense the presence of smoke particles produced by fast combustion or slow smoldering fire.
SNC-100-S2 detector incorporates well proven sensing technologies, together with advances in materials and electronics technology, and represents the pinnacle of fire detector performance and reliability.
SNC-100-S2 detector is advanced photoelectric smoke detection which is made with an innovative and modern design, every unit is individually tested and calibrated to ensure high reliability and prevent false alarms.
The detector will work with most modern fire alarm control panels, and meets the requirements of UL 268 and EN 54-7

Features:
1) 2-Wire operation
2) Wide operating voltage
3) Advanced electronic technology
4) Proven detection performance
5) Designed to meet approvals worldwide (e.g. UL LPCB CE)
6) Sensor base: optional installation and wiring mode
Specification:
MODEL
SNC-100-S2
DETECTOR CLASS
Photoelectric Smoke
SUPPLY WIRING
2 – WIRE
DESIGN STANDARD
EN 54-7 and UL 268
APPROVAL
CE; LPCB and UL Pending
SUPPLY VOLTAGE
10.8 to 33V DC
QUIESCENT CURRENT
60μA @24V
ALARM CURRENT
50mA@24V
TEMPERATURE RANGE
-10℃ to +55℃
HUMIDITY
0% to 95% RH No Condensation
SENSITIVITY
UL:2.3%FT; EN 54:0.15dB/m
IP RATING
IP 43
START-UP TIME
10 Seconds
DIMENSIONS (dia. x height)
99 x 46mm (with Base)
WEIGHTS
130g


Conventional 2-wire photoelectric smoke detector

Post Buying Request