Neurocare Modular Patient Monitor

500.0~5000.0 USD
Min. Order: 1 Piece/Pieces

Company Profile

Location: Hong Kong
Business Type: Manufacturer, Trading Company
Main Products: Fetal Heart Rate Monitor, Doppler Detector Baby Monitor, Ultrasonic Transducer Ultrasonic Monitor, Neurocare Series Patient Monitor, Fetal Monitor Maternal Monitor

Product Detail

Model No.: Neuroplus-PM-X6
Packing: carton

Product Description

Features:
1Plug-in modular design, all modules support hot plug with free combination, convenient to use, maintain and upgrade
2Professional EEG monitoring to make it more perfect
3 15/17/19 inch high definition color display
4 Standard six-parameter module: ECG, HR, NIBP, SpO2, RESP and TEMP
5 Powerful software functions, to show full range of information reports
6 3 level intelligent alarms: sound, light and voice alert, volume adjustable
7Compatible with central monitoring system
8 Optional modules: EEG/PSG, EtCO2, IBP, CSI (cerebral state index);
9 Expandable EEG or EEG&PSG module for brain function and polysomngraphic recording:
1. Independent EEG module is 8/16/32 channels optional
2. Integrated EEG$PSG module including: EEG(8/16 channels);EOG (2 channels); EMG (1 channel); SNORING (1 channel ); AIRFLOW (1 channel ); ABDOMINAL (1 channel )
ECG
Lead type: 3/5 leads electric cable
Input: 3 leads: RA, LA, LL (Lead method: I, II, III)
5 leads: RA, LA, LL, RL, V (Lead method: I, II, III, aVR, aVL, aVF, V)
Gain: ´250, ´500, ´1000, ´2000
Heart rate range: 15~300bpm (adult), 15~350bpm (child & neonate)
Accuracy: ±1bpm or ±1%, whichever is bigger
Resolution: 1bpm
Sensitivity: >200uV (peak to peak)
Input impedance: >5MΩ
Bandwidth: Diagnosis model: 0.05~130Hz, Monitoring: 0.5~40Hz, Operation: 1~20Hz
CMRR: Diagnosis model: >90dB, Monitoring model: >100dB, Operation model: >100dB
Electrode polarization and voltage range: ±300mV
Pacemaker impulses Amplitude: ±2mV~ ±700mV, Width: 0.1ms~2ms, Rise time: 10us~100µs
Recovery time: < 3 seconds
Signal range: ±8 mV peak to peak
Calibrate signal: 1mV peak to peak; accuracy: ±5%
ST detection: Range: -2.0mV~ +2.0Mv, Accuracy: -0.8 mV~ +0.8mV, Error: ±0.02mV/±10%
Arrhythmia analysis (13 kinds):
NIBP (Noninvasive blood pressure)
Method: Pulse wave oscillation
Operation mode: Manual/Automatic/Continuous
Time interval (Automatic): 1min, 2mins, 3mins, 4mins, 5mins, 10mins, 15mins, 30mins, 60mins, 90mins, 2hours, 3hours, 4hours, 8hours
Time interval (Continuous): 5mins
Range: Adult: Systolic blood pressure: 40~280mmHg
Diastolic blood pressure: 10~220mmHg
Mean pressure: 20~240mmHg
Child: Systolic blood pressure: 40~220mmHg
Diastolic blood pressure: 10~160mmHg
Mean pressure: 20~170mmHg
Neonate: Systolic blood pressure: 40~135mmHg
Diastolic blood pressure: 10~100mmHg
Mean pressure: 20~110mmHg
Static pressure range: 0~300mmHg, Static pressure accuracy: ±3mmHg
Maximum average deviation: ±3mmHg; Maximum standard deviation: ±6mmHg
Over-pressure protection: 300 mmHg (adult), 240 mmHg (child), 150 mmHg (neonate)
SpO
Range: 0~100%
Resolution: 1%
Accuracy: ±1% (70~100%), ±2% (40%~69%), not defined (<39%)
Respiration
Method: RA-LL impedance
Range of respiratory impedance: 0.3~3Ω
Base impedance range: 200~4000Ω
Bandwidth: 0.1~2.5Hz
Gain: ´0.25, ´0.50, ´1, ´2, ´4
Respiration rate: 7~120BrPM (adult), 7~150BrPM (child & neonate)
Resolution: 1BrPM
Accuracy: ±2BrPM
Apnea Alarm: 10~40 second selectable
Temperature
Sensor type: 10K series, 2.25K series
Channels: 2channels
Range: 0~50°C
Resolution: 0.1°C
Accuracy: ±0.1°C (25°C ~45°C), ±0.2°C (0°C ~25°C, 45°C ~50°C)