Application: | Neonatal, pediatric & adult |
Design: | Flexible 6-parameter module |
Production Capacity: | 100 sets per week |
Packing: | 260*410*530 mm |
Delivery Date: | 3-5 working days |
Features
1. Modular designwith higher integration, more stable functions, and lower power consumption,easy to replace
2. 12inch high definition color TFT display
3. AC/DCavailable, suitable for ward bedsides, ICU care and Operating Room
4. Standardsix-parameter module: ECG, HR, NIBP, SpO2, RESP and TEMP
5. Monitor andanalysis: arrhythmia analysis, ST segment analysis, drug concentration andtitration table calculation
6. NIBPmeasurement using a double overpressure protection technology to prevent injuryfrom high inflation pressure
7. 720hours of trend data playback, 2 hours of waves playback, up to 1000 BP review,up to 200 alarm events review
8. 3-levelintelligent alarms: sound, light and voice alert, volume adjustable
9. Supportwired networking, support mixed network connection
ECG
Lead type: 3/5 leads electric cable
Input: 3 leads: RA, LA, LL (Lead method: I, II, III)
5 leads: RA, LA, LL, RL, V (Lead method: I, II, III, aVR, aVL, aVF, V)
Heart rate range: 15~300bpm (adult), 15~350bpm (child & neonate)
Accuracy: ±1bpm or ±1%, whichever is bigger
ST detection: Range: -2.0mV~ +2.0mV, Accuracy: -0.8 mV~ +0.8mV
Arrhythmia analysis: 13 kinds
NIBP (Noninvasive blood pressure)
Method: Pulse wave oscillation
Operation mode: Manual/Automatic/Continuous
Time interval (Automatic):1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480mins
Time interval (Continuous): 5mins
Range:Adult: Systolic blood pressure: 40~280mmHg
Diastolic blood pressure: 10~220mmHg
Mean pressure: 20~240mmHg
Child: Systolic blood pressure: 40~220mmHg
Diastolic blood pressure: 10~160mmHg
Mean pressure: 20~170mmHg
Neonate: Systolic blood pressure: 40~135mmHg
Diastolic blood pressure: 10~100mmHg
Mean pressure: 20~110mmHg
SpO2 (finger pulse oximetry)
Range: 0~100%
Resolution: 1%
Accuracy: ±1% (70~100%), ±2% (40%~69%), not defined (<39%)
Respiration
Method: RA-LL impedance
Range of respiratory impedance: 0.3~3 ohm
Respiration rate:7~120BrPM (adult), 7~150BrPM (child & neonate)
Temperature
Sensor type: 10K series, 2.25K series
Channels: dual channels