Applications:
For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between
primary (high voltage) and the secondary (electronic) circuits.
Main technical data:
1. Primary normal voltage VPN: 1000V r.m.s
2. Primary voltage, measuring range IP: 0~+/-1500V
3. Secondary nominal output: 50mA r.m.s
4. Measuring resistance: RMmin RMmax
with +/-15V @ +/-1000V max: 0 ohm 200 ohm
@ +/-1500V max: 0 ohm 70 ohm
with +/-24V @ +/-1000V max: 60 ohm 360 ohm
@ +/-1500V max: 60 ohm 150 ohm
5. Supply voltage (+/-10%): +/-15V~+/-24V
6. Current consumption: ≤ 30mA+ Secondary output current
7. Isolation test: Between the primary circuit and the secondary circuit (+.-.M): 6kVrms/50Hz/1min
Accuracy – Dynamic performance data:
1. Accuracy ≤±0.7%(@+25℃)
2. Non-linearity ≤±0.2mA(@+25℃)
3. Offset current ≤0.1%
4. Thermal drift: ≤± 0.8mA(-40℃~+85℃)
5. Response time @90% of VPmax: not more than 60us
6. dV/dt:≥100V/us
General data:
1. Operating temperature: -40oC~+85oC
2. Storage temperature: -40 C ~+90 C
3. Primary resistance @ TA=+25 C: 100 kilohm
4. Secondary coil resistance: not more than 60 ohm
5. Weight: 850g×(1±20%) g
6. Standards: EN 50155
Features:
1. Hall effect measuring principle
2. Galvanic isolation between primary and secondary circuit
3. Insulated plastic case made of black PPO recognized according to UL 94-V0
Dimension:
Connection: