Applications:
For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between the
primary (high voltage) and the secondary (electronic) circuits.
Main technical data:
1. Primary normal current IPN: 10mA r.m.s
2. Primary current, measuring range IP: 0~+/-14mA
3. Primary normal current IPN: 4mA r.m.s
4. Measuring resistance: RMmin RMmax
with +/-15V @ +/-10mA max: 100 ohm 340 ohm
@ +/-14mA max: 100 ohm 180 ohm
5. Secondary nominal output: 25mA rms
6. Conversion ratio: 2500:1000
7. Supply voltage (+/-5%): +/-15V
8. Current consumption: 10mA+ Secondary normal current
9. Isolation test: Between the primary circuit and the secondary circuit(+.-.M): 4.1kVrms/50Hz/1min
Accuracy – Dynamic performance data:
1. Accuracy @ VPN, TA=+25 C: ≤+/-0.8%
2. Non-linearity: @ VPN,TA=+25℃:±0.2%
3. Offset current ≤±0.15mA(@+25℃)
4. Thermal drift: +/-0.5mA(-25 C ~+85 C)
+/-0.8mA(-40 C ~+85 C)
5. Response time @90% of VPN: not more than 40us
General data:
1. Operating temperature: -40oC~+85oC
2. Storage temperature: -50 C ~+90 C
3. Primary coil resistance @ TA=+85 C:<300 ohm
6. Secondary coil resistance: not more than 117 ohm
7. Weight: 22g
8. Standards: EN 50155
Features:
1. Hall effect measuring principle
2. Galvanic isolation between primary and secondary cir
3. Insulated plastic case made of white PPO recognized a
4. The whole voltage transducer comply with RoHS Dire
Dimension:
Connection: