Applications:
For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between the
primary (high voltage) and the secondary (electronic) circuits.
Main technical data:
1. Primary normal voltage VPN: 2000V r.m.s
2. Primary voltage, measuring range IP: 0~+/-3000V
3.Secondary nominal output: 50mA r.m.s
4. Supply voltage(+/-10%): +/-15V~+/-24V
5. Current consumption: 30mA(@+/-24V)+ Secondary output current
6. Isolation test: Between the primary circuit and the secondary circuit(+.-.M.E): 9kVrms/50Hz/1min
Between the secondary circuit(+.-.M) and the ground-screen(E): 1kVrms/50Hz/1min
Accuracy – Dynamic performance data:
1. Accuracy @ VPN, TA=+25 C: +/-0.7%
2. Non-linearity @ VPN, TA=+25 C: +/-0.1%
3. Offset current ≤±0.2mA(@+25℃)
4. Thermal drift: +/-0.8mA(-40 C ~+85 C)
5. Response time @90% of VPmax: not more than 60us
General data:
1. Operating temperature: -40oC~+85oC
2. Storage temperature: -40 C ~+85 C
3. Turns ratio: 20000:2000
4. Primary resistance @ TA=+25 C: 400 kileohm
5. Secondary coil resistance: not more than 60 ohm
6. Weight: 850g
7. Standards: EN 50155
Features:
1. Hall effect measuring principle
2. Galvanic isolation between primary and seconda
3. Insulated plastic case made of black PPO recogn
Dimension:
Connection: