NVCL.400B-11 Voltage Transducer

Min. Order: 1000 Piece/Pieces
Payment Terms: T/T
Supply Ability: 10000 Piece/Pieces per Month
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company, Agent, Distributor/Wholesaler

Product Detail

Model No.: NV200-400V
Means of Transport: Ocean
Output: Switching Transducer
Theory: Hall Sensor
Usage: Level Sensor
Primary normal voltage: 400V
Production Capacity: 10000 Piece/Pieces per Month
Packing: According to customer's request
Delivery Date: 15 --20 days
Show

Product Description

Applications:                                             
For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between the
primary (high voltage) and the secondary (electronic) circuits.

Main technical data:
1. Primary normal voltage VPN: 400V r.m.s
2. Primary voltage, measuring range IP: 0~+/-600V
3. Secondary nominal output: 80mA rms
4. Supply voltage(+/-10%): +/-15V~+/-24V  
5. Current consumption: 35mA(@+/-24V)+ Secondary output current
6. Isolation test:   Between the primary circuit and the secondary circuit(+.-.M.E): 6kVrms/50Hz/1min
Between the secondary circuit(+.-.M) and the ground-screen(E): 1kVrms/50Hz/1min

Accuracy – Dynamic performance data:
1. Accuracy @ VPN, TA=+25 C: +/-1%
2. Non-linearity @ VPN, TA=+25 C: better than +/-0.1%
3. Offset current ≤±0.5mA(@+25℃)
4. Thermal drift:   +/-0.5mA(0 C ~+70 C)
5. Response time @90% of VPmax: 50us

General data:
1. Operating temperature: 0oC~+70oC
2. Storage temperature: -40 C ~+85 C
3. Turns ratio: 5000:2500
4. Total primary power loss: 8W
5. Primary resistance @ TA=+25 C: 20 kilohm
6. Secondary coil resistance: not more than 40 ohm
7. Weight: 2kg  
8. Standards: EN 50178

Features:
1. Hall effect measuring principle
2. Galvanic isolation between primary and secondary circuit
3. Insulated plastic case made of black PPO recognized according to UL 94-V0

Dimension:
NV200-400V Voltage Transducer
Connection:
NV200-400V Voltage Transducer

Post Buying Request