Applications:
For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between the
primary (high voltage) and the secondary (electronic) circuits.
Main technical data:
1. Primary normal voltage VPN: 3000V r.m.s
2. Primary voltage, measuring range IP: 0~+/-4500V
3. Secondary normal current: 80mA rms
4. Supply voltage (+/-10%): +/-15V~+/-24V
5. Current consumption: (35±5)mA+ Secondary output current
6. Isolation test: Between the primary circuit and the secondary circuit(+.-.M.E): 9.5kVrms/50Hz/1min
Between the secondary circuit(+.-.M) and the ground-screen(E): 1kVrms/50Hz/1min
Accuracy – Dynamic performance data:
1. Accuracy @ VPN: ±1%(-10oC~+50oC)
2. Non-linearity @ VPN: ±0.2%(20℃℃±5 )
3. Offset current: ≤±0.5mA
4. Response time @90% of VPmax: 200us
General data:
1. Operating temperature: -25oC~+70oC
2. Storage temperature: -40 C ~+85 C
3. Weight: 2kg
4 Standards: EN 50155
Features:
1. Hall effect measuring principle
2. Galvanic isolation between primary and secondary circuit
3. Insulated plastic case made of black PPO recognized according to UL 94-V
Dimension:
Connection: