Description
Input voltage range 88-132VAC/176-264VDC
Input frequency 47-63HZ
Inrush current Cold Start, 30A/115VAC, 50A/230VAC
Output adjustment range CH1: - 5% ~+10% rated output range
Line regulation: ≤0.5%
Output over-load protection 105%-135% Shut off, AC recycle to re-start
Output over voltage protection CH1: 115%-135% Rated output voltage
Output short circuit protection Shut off, AC recycle to re-start
Rise, hold up time 50mS, 20mS at full load (typical)
Hi-pot isolation I/P-O/P: 3KVAC,I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC
Operating temperature range 0℃ to +50℃@100%,-10℃@80%,+60℃@60% load
Storage temperature range -40℃ to +85℃,0 to 95%RH(Non-condensing)
Safety standards UL60950-1, TUV EN60950-1
EMC standards EN55022 class B, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling method Forced air cooling convection
Weight 0.86kg/pc