120W Multiple Output Power Supply Q-120 Series
Features:
AC input range selected by switch
Protections: Short circuit / Overload / Over voltage
100% full load burn-in test
Fixed switching frequency at 25 KHz
1 year warranty
120W Multiple Output Power Supply Q-120 Series SpecificationMODEL | Q-120B | Q-120C | Q-120D |
OUTPUT | OUTPUT NUMBER | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 |
DC VOLTAGE | 5V | 12V | -5V | -12V | 5V | 15V | -5V | -15V | 5V | 12V | 24V | -12V |
RATED CURRENT | 11A | 4A | 1A | 1A | 10A | 3.5A | 1A | 1A | 8A | 2A | 2A | 1A |
CURRENT RANGE | 2 ~ 12A | 0.5 ~ 5A | 0.2 ~ 1A | 0.2 ~ 1A | 2 ~ 12A | 0.5 ~ 5A | 0.2 ~ 1A | 0.2 ~ 1A | 2 ~ 12A | 0.2 ~ 5A | 0.2 ~ 2A | 0.2 ~ 1A |
RATED POWER | 120W | 122.5W | 124W |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 80mVp-p | 120mVp-p | 80mVp-p | 150mVp-p | 80mVp-p | 150mVp-p | 80mVp-p | 120mVp-p | 180mVp-p | 120mVp-p |
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5 |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±6.0% | ±6.0% | ±6.0% | ±2.0% | +10,-5% | ±6.0% | +10,-5% | ±2.0% | ±6.0% | ±6.0% | ±6.0% |
LINE REGULATION | ±0.5% | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±1.0% | ±1.0% | ±1.0% |
LOAD REGULATION | ±0.5% | ±5.0% | ±5.0% | ±5.0% | ±0.5% | ±6.0% | ±5.0% | ±6.0% | ±0.5% | ±5.0% | ±5.0% | ±5.0% |
SETUP, RISE, HOLD TIME | 200ms, 50ms, 20ms at full load |
INPUT | VOLTAGE RANGE | 88 ~ 132VAC/176 ~ 264VAC selected by switch240 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz |
EFFICIENCY (Typ.) | 77% | 76% | 80% |
AC CURRENT | 2.8A/115VAC1.6A/230VAC |
INRUSH CURRENT (max.) | COLD START 35A |
LEAKAGE CURRENT | <3.5mA / 240VAC |
PROTECTION | OVERLOAD | 105~135% rated output power |
Protection type: Shut down o/p voltage, re-power on to recover. |
OVER VOLTAGE | CH1: 5.75 ~ 6.75VDC |
Protection type: Shut down o/p voltage, re-power on to recover. |
ENVIRONMENT | WORKING TEMP. | -10~+60ºC |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY & EMC (Note 4) | SAFETY STANDARDS | Design refer to UL1950, TUV EN60950 |
WITHSTAND VOLTAGE | I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
HARMONIC CURRENT | Compliance to EN61000-3-2,-3, Class A |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A |
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B |
OTHERS | MTBF | 261.4K hrs min. MIL-HDBK-217F (25ºC) |
DIMENSION | 199*110*50mm (L*W*H) |
PACKING | 0.81Kg; 16pcs/14.51Kg/0.0287CMB |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºCof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
120W Multiple Output Power Supply Q-120 Series Mechanical Specification:
120W Multiple Output Power Supply Q-120 Series Certificate for LVD:
120W Multiple Output Power Supply Q-120 Series Certificate for EMC: