Blood Gas Analyzer

Min. Order: 1 UNIT
Payment Terms: T/T
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company

Product Detail

Model No.: 600166
Means of Transport: BY SEA /BY AIR
Brand Name: LifeCare
Function: MEDICAL USE
Certificate: CE .ISO9001,13485
Export Area: EUROPE /ASIA /MIDDLE EAST
Packing: CASE
Delivery Date: 10DAYS
Show

Product Description

Features:
  • Continuing calibration, the analyzer is always in a good
    situation ready for measurement at any time. This asures the
    accuracy of measurement results.
  • The analyzer uses mutual bar formation electrode, reliable
    function, can replace the membrane and inner solution to
    lengthen the using time and lower the cost.
  • Flushing solution can get rid of the dirty and reduce pollution to
    extend the use life of the electrode. This lowers the unit
    consumption and cost.
  • The sampling case is transparent, the temperature, electrode
    drift and lack of calibrating solution can be showed
    automatically.
  • The rich-contented servicing program provides operators many
    options(e.g. the channel breaks), so that operators judge the
    reason of the trouble.
  • Inner thermal printer can print measurement result
    immediately.
  • Can store 1000 patient datas.
  • It is equipped with a standard RS232 serial port, via which the
    instrument transfers its saved data to the connected computer
    system.
Parameters:
  • Sample volume: 90 μl whole blood or body liquid, gas sample
    (e.g.: exhalant gas) 30ml.
  • Sample quantity per hour: 25.
  • Sampling case temperature: 37.0±0.1℃.
  • Working environment: temperature 10~35℃, relevant humidity
    85% (no water).
  • Power: AC220V±10%;
    Frequency: 50Hz±2%;
    Power input:≤170VA.
  • Size: 470mm×360mm×430mm
  • Weight: 10KGS
Measurement parameters:
Test
Item
Test Range Accuracy Error Deviation
PH 6.800~8.00 0.001 ±0.010 S≤0.005
PCO2 8.0~200.0mmHg 0.1mmHg ±4.0%
±0.13kPa if PCO2≤3.3kPa
CV≤1.5%
1.61~26.67kPa 0.1kPa
PO2 0~800.0mmHg 0.01mmHg ±3.0%
±0.26kPa if PO2≤8.0kPa
CV≤1.5%
0~106.7kPa 0.1kPa
Calculating parameters:
HCO2 P50
SBC A-aDO2
BE RI
BeecI PH(TC)
TCO2 PCO2(TC)
SO2% PO2(TC)
Specifications of Electrode:
Stability Excellent
Repeatability pH: S≤0.005
PCO2: CV≤1.5%
PO2: CV≤1.5%
Reaction Time <5S
Life >12 months

Mainframe:  590mm×480mm×550mm  N.W.17kgs  G.W.19kgs
Accessory:  360mm×360mm×420mm    N.W.7kgs  G.W.8kgs