Product Name : Syringe Pump
Model No. : MR-SP500II

Technical parameters of 500II Syringe pump
Applicable syringes
All brands of standard syringes: 5ml,10ml,20ml,30ml,50ml
Weight
<3.0kg
Accuracy
±2%
Dimension
380×190×180mm
Injection increment
0.1ml
Power supply
AC100~240V, 50/60Hz
Occlusion value
40kPa~160kPa
Fuse
T2AL250V~
Injection rate
5ml: 0.1 ml/h -100ml/h   30ml: 0.1 ml/h -600ml/h
10ml: 0.1 ml/h -200ml/h  50ml: 0.1 ml/h -1500ml/h
20ml: 0.1 ml/h -400ml/h       
Maximum power consumption
25W, can run for 4h after being recharged
Battery
Rechargeable lithium polymer battery, 7.4V, 1600mAh
Accumulated injection volume
0.1ml~9999.9ml
Battery recharge
When the pump is connected to the AC power supply, turn on the power and the battery will automatically recharge (about 8~14 hours to recharge fully.)
Modes of operation
Selectable: Rate mode, Time mode, Body Weight mode
Time mode
Volume limit: 0.1~999.9ml  Time: 1~2000 minutes
Electrical safety
Comply with the stipulation of IEC60601-1: 1996
Body weight mode
Drug limit:0.1~999.9mg, Solution limit:0.1~999.9ml, Weight: 01~300.0kg, Dose: 0.1~9999.9 mg/kg/h, ug/kg/min
Electromagnetic compatibility  
Comply with the stipulation of IEC60601-1-2: 2006
Displayed information
Rate, volume limit, accumulated injection volume, syringe size, pressure value, battery capacity, unit of medical dosage, bed No., AC power indicator, battery charge indicator, drug name, bolus rate
Shell material
ABS plastic
Classification
II Class-BF
Alarm function
OVER, NEAR, Occlusion, Low battery, Syringe disengaged, No AC power supply, serious low battery
Operating conditions
Environment temperature 5°C ~40°C, air pressure 80kPa ~106kPa, relative humidity ≤80%
Storage conditions
Environment temperature -40°C~55°C, air pressure 50kPa ~106kPa, relative humidity ≤95%
KVO rate
0.1ml/h-5.0ml/h (selectable)
Applied standards
IEC60601-1: 2005
IEC60601-2-24: 1998
IEC60601-1-2: 2006
ISO780-1997
ISO15223: 2000
ISO7886-1: 1993
ISO / IEC: Guide No. 37
Bolus rate
5ml: 100ml/h
10ml: 200ml/h
20ml: 400ml/h
30ml: 400ml/h-600ml/h
50ml: 400ml/h-1500ml/h
Function and Features
1.Three kinds of modes: Rate Mode, Time Mode, Body Weight Mode.
2.Double CPU, making the process of injection safer and more reliable.
3.Accurate and sensitive pressure sensor detecting occlusion pressure accurately.
4.Injection time, dose, solution can be checked during the process of injection.
5.Precision step motor. There is no pulsating wave even during low-rate injection.
6.KVO rate can be selectable according to concrete requirements from 0.1ml/h to 5ml/h.
7.Excellent injection operation. The accuracy will be ensured even at small-volume injection.
8.Unique injection supervision system ensures the safe injection and reduces the nurse's workload.
9.Accept all standard syringes of 5ml, 10ml, 20ml, 30ml and 50ml. It will self-diagnose and display the syringe size and set parameter automatically in the form of menu.
10.Alarm is given when there is malfunction or operation error, and the machine stops running automatically.
11.Save the preset volume automatically when there is unpredictable switch off, ensuring the accuracy of injection volume.
Post Buying Request