Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB |
Payment Terms: | L/C, T/T, WU |
Supply Ability: | 5000 sets per month |
Place of Origin: | Zhejiang |
Location: | Ningbo, Zhejiang, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company, Agent |
Main Products: | ENT Unit, First Aid Kit Promotional, Aneroid Sphygmomanometer, Car First Aid Kit, Dental Autoclave |
Model No.: | MR-SP500II |
---|---|
Means of Transport: | Ocean |
Brand: | MIRO |
Production Capacity: | 5000 sets per month |
Packing: | standard export carton |
Delivery Date: | 20days |
Applicable syringes | All brands of standard syringes: 5ml,10ml,20ml,30ml,50ml | Weight | <3.0kg |
Accuracy | ±2% | Dimension | 380×190×180mm |
Injection increment | 0.1ml | Power supply | AC100~240V, 50/60Hz |
Occlusion value | 40kPa~160kPa | Fuse | T2AL250V~ |
Injection rate | 5ml: 0.1 ml/h -100ml/h 30ml: 0.1 ml/h -600ml/h 10ml: 0.1 ml/h -200ml/h 50ml: 0.1 ml/h -1500ml/h 20ml: 0.1 ml/h -400ml/h | Maximum power consumption | 25W, can run for 4h after being recharged |
Battery | Rechargeable lithium polymer battery, 7.4V, 1600mAh | ||
Accumulated injection volume | 0.1ml~9999.9ml | Battery recharge | When the pump is connected to the AC power supply, turn on the power and the battery will automatically recharge (about 8~14 hours to recharge fully.) |
Modes of operation | Selectable: Rate mode, Time mode, Body Weight mode | ||
Time mode | Volume limit: 0.1~999.9ml Time: 1~2000 minutes | ||
Electrical safety | Comply with the stipulation of IEC60601-1: 1996 | ||
Body weight mode | Drug limit:0.1~999.9mg, Solution limit:0.1~999.9ml, Weight: 01~300.0kg, Dose: 0.1~9999.9 mg/kg/h, ug/kg/min | ||
Electromagnetic compatibility | Comply with the stipulation of IEC60601-1-2: 2006 | ||
Displayed information | Rate, volume limit, accumulated injection volume, syringe size, pressure value, battery capacity, unit of medical dosage, bed No., AC power indicator, battery charge indicator, drug name, bolus rate | Shell material | ABS plastic |
Classification | II Class-BF | ||
Alarm function | OVER, NEAR, Occlusion, Low battery, Syringe disengaged, No AC power supply, serious low battery | Operating conditions | Environment temperature 5°C ~40°C, air pressure 80kPa ~106kPa, relative humidity ≤80% |
Storage conditions | Environment temperature -40°C~55°C, air pressure 50kPa ~106kPa, relative humidity ≤95% | ||
KVO rate | 0.1ml/h-5.0ml/h (selectable) | Applied standards | IEC60601-1: 2005 IEC60601-2-24: 1998 IEC60601-1-2: 2006 ISO780-1997 ISO15223: 2000 ISO7886-1: 1993 ISO / IEC: Guide No. 37 |
Bolus rate | 5ml: 100ml/h 10ml: 200ml/h 20ml: 400ml/h 30ml: 400ml/h-600ml/h 50ml: 400ml/h-1500ml/h |