Major Technical Indications:
· Host dimensions: 218 x 145 x 40mm
· Extension dimensions: 140 x 120 x 18mm
· Host power consumption: ≤4W
· Extension power consumption: ≤0.6W
· Maximum number of extension: 3 sets
· Maximum distance between host and extension: 100m
· Accuracy of temperature measuring: ±2°C
· Collector module's temperature measuring range: 0 to 120°C
· Other range of temperature measuring: 0 to 100°C
· Controllable circulation pump power: ≤500W
· Controllable ribbon heater power: ≤500W
· Controllable electric heating power: ≤3,000W
· Inputs:
o 1 x PT1000 sensor for collector
o 3 pieces x NTC3435 temperature sensor (top of tank, bottom of tank and pipeline)
· Outputs:
o Auxiliary heating
o Collector temp-difference circulation pump
o Water pipeline circulation pump
o Frost protection output
o Tank high temperature coil pipe circulation pump
Main Functions:
1. Collector temperature difference circulation
2. Collector frost protection
3. Collector high temperature protection
4. Tank high temperature protection
5. Pipeline circulation in the position of using water
6. Auxiliary heating
7. Ribbon heater pipeline frost-protection