 1.Power capacitor should confirm left voltage reduce to rated voltage 10% to input again after the power
was cut off ,normally it will need 200s almost. so it would choose the power controller which has input
and reput lock time function after cut off the power. If choose normally power controller, it must install
speediness discharge power equipment .it would not limited which use adopting same electric factor
input and chip switch.
2. Altitude level is not more than 2000m.
3. Temperature type: -25/C low temperature, highest temperature is C type (it would not more than 50
the average of temperature is not more than 40 within 24 hours, one year average of temperature
is not more than 30 ),power capacitor will work within good ventilate condition. It would not permit within sealing and installation condition
1. Rated voltage: 230V, 250V, 400V, 450V, 525V, 690V, 750V, 1050V, 1200V, other special voltage please notice it .
2. Rated capacity: 0.4~0.69kV 1~60kvar, other voltage class's capacity ,please notice it
3. Rated frequency: 50Hz or 60Hz.
4. Capacity tolerance: -5%~+10%.
5. Loss angle tan 0.1% when the temperature is 20
6. Anti voltage :between two pole 2.15 time rated voltage is 10 s, between two pole 2Un+2kV or 3kV please choose highest value 10 s , there is no
perpetuity puncture and flashover
7. Max permit over voltage : 1.1 time rated voltage ,the high permit over voltage is not more than 8 hours within 24 hours . 1.15 time rated voltage ,it is
not more than 30 minute within 24 hours ,1.2 time rated voltage it is not more than 5 minute ,1.3 times rated voltage ,it would not more than 1 minute
8. Max permit over current : it is permit that the over current is not more than 1.3 time rated current ,interim over current it should consider over voltage,
capacity positive tolerance and harmonic effect .interim over current is not more than 1.43 time rated current .
9. Connection: Y type ,Y type should draw out through neuter ,III three section ,single phase type ,and all kind of connection way .other connection
way it will notice when you order it
10. Discharge property : the left voltage will reduce from 2Un to below 50V within 3 minutes when the power cut off