bearing bar section (mm) | grid pitch | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | weight(kg/m2) | 20X2 | 31.62 | 21.08 | 16.12 | 13.02 | 10.54 | 9.3 | 8.37 | 7.44 | 6.82 | 6.2 | 5.58 | 25X2 | 39.78 | 26.52 | 20.28 | 16.38 | 13.26 | 11.7 | 10.53 | 9.36 | 8.58 | 7.8 | 7.02 | 30X2 | 47.94 | 31.96 | 24.44 | 19.74 | 15.98 | 14.1 | 12.69 | 11.28 | 10.34 | 9.4 | 8.46 | 25X3 | 60.18 | 40.12 | 30.68 | 24.78 | 20.06 | 17.7 | 15.93 | 14.16 | 12.96 | 11.6 | 10.62 | 30X3 | 72.42 | 48.28 | 36.92 | 29.82 | 24.14 | 21.3 | 19.17 | 17.04 | 15.62 | 14.2 | 12.78 | 35X3 | 83.64 | 55.76 | 42.64 | 34.44 | 27.88 | 24.8 | 22.14 | 19.68 | 18.04 | 16.4 | 14.76 | 40X3 | 95.88 | 63.92 | 48.88 | 39.48 | 31.96 | 28.2 | 25.38 | 22.56 | 20.68 | 18.8 | 16.92 | 25x5 | 99.96 | 66.64 | 50.96 | 41.16 | 33.32 | 29.4 | 26.46 | 23.52 | 21.56 | 19.6 | 17.64 | 30x5 | 120.36 | 60.24 | 61.36 | 49.56 | 40.12 | 35.4 | 31.86 | 28.32 | 25.96 | 23.6 | 21.24 | 35x5 | 139.74 | 93.16 | 71.24 | 57.54 | 46.58 | 41.1 | 36.99 | 32.88 | 30.14 | 27.4 | 24.66 | 40x5 | 160.14 | 106.76 | 81.64 | 65.94 | 53.38 | 47.1 | | | | | | 45x5 | 180.54 | 120.36 | 92.04 | 74.34 | 60.18 | 53.1 | 47.79 | 42.48 | 38.94 | 35.4 | 31.86 | 50x5 | 199.92 | 133.28 | 101.92 | 82.2 | 66.64 | 58.8 | 52.92 | 47.04 | 43.12 | 39.2 | 35.28 | 55x5 | 220.32 | 148.88 | 112.32 | 90.72 | 73.44 | 64.8 | 58.32 | 51.84 | 47.52 | 43.2 | 38.88 | 60x5 | 288.66 | 160.48 | 122.72 | 99.12 | 80.24 | 70.8 | 63.72 | 56.64 | 51.92 | 47.2 | 42.48 | nominal width (mm) | 1002 | 992 | 1002 | 1002 | 962 | 982 | 962 | 992 | 1002 | 992 | 962 |
|
Note; 1. Markup example: HG303/30 ( "HG" plug grille plate mark; "303" flat steel section size [width X thickness] mm; "30" grid spacing mm; 2. Bian Nominal width is the key link by calculating a thickness of 2mm, if the thickness of 5mm, should be coupled with 3mm. 3. In addition to this page from the table cells, but also can be processed according to user needs in different cells from the other.
|
| | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | weight(kg/m2) | 20X2 | 10.9 | 7.27 | 5.56 | 4.49 | 3.63 | 3.21 | 2.89 | 2.57 | 2.35 | 2.14 | 1.92 | 25X2 | 13.72 | 9.14 | 6.99 | 5.65 | 4.57 | 4.03 | 3.63 | 3.23 | 2.96 | 2.69 | 2.42 | 30X2 | 16.53 | 11.02 | 8.43 | 6.81 | 5.51 | 4.86 | 4.38 | 3.89 | 3.57 | 3.24 | 2.92 | 35X2 | 19.38 | 12.92 | 9.88 | 7.98 | 6.46 | 5.7 | 5.13 | 4.56 | 4.18 | 3.8 | 3.42 | 40X2 | 22.44 | 14.96 | 11.44 | 9.24 | 7.48 | 6.6 | 5.94 | 5.28 | 4.84 | 4.4 | 3.96 | 20X3 | 16.52 | 11.01 | 8.42 | 5.81 | 5.51 | 4.86 | 4.37 | 3.89 | 3.55 | 3.24 | 2.92 | 25X3 | 20.75 | 13.83 | 10.58 | 8.54 | 6.92 | 6.1 | 5.49 | 4.88 | 4.48 | 4.07 | 3.66 | 30x3 | 24.97 | 16.65 | 12.73 | 10.28 | 6.32 | 7.34 | 6.61 | 5.88 | 5.39 | 4.9 | 4.41 | 35x3 | 28.84 | 19.23 | 14.7 | 11.88 | 9.61 | 8.55 | 7.67 | 6.79 | 6.22 | 5.66 | 5.09 | 40x3 | 33.06 | 22.04 | 16.86 | 13.61 | 11.02 | 9.72 | 8.75 | 7.78 | 7.13 | 6.48 | 5.83 | | 1002 | 992 | 1002 | 1002 | 962 | 982 | 982 | 992 | 1002 | 992 | 962 |
|
Note; 1. Markup example: HG302/30 ( "HG" plug grille plate mark; "303" flat steel section size [width X thickness] mm; "30" grid spacing mm; 2. Bian Nominal width is the key link by calculating a thickness of 2mm, if the thickness of 3mm, should be coupled with 1mm. 3. In addition to this page from the table cells, but also can be processed according to user needs in different cells from the other.
|