HID Conversion Kits
Includes
1.2 ballast
2.2 single lights
3.2 Fixing Pads
4. Screws and Wiring's
5.Users' Manual
6. Color Box
Ballast Parameter
Model No:FS10
1. Working voltage ranged: 9 to 16V DC
2. Working current:3.2A(at 12V DC)
3. Input voltage: 12V DC
4. Input current when turn on the light: <5.5A
5 .Instantaneous voltage when turn on the light: 23+_ 1kv
6. Output power:35w
7. Working temperature range:-40 to +105 degrees Celsius
8 .Output load: one HID 35W lamp
9. EMI electromagnetic compatible standard to the ballast:S95, 54 and EC
10.Reverse polarity protection: Short/ open-circuit protection
11.Shock,water and dust-resistant protection
12.Size:10.8x6.5x2.3CM
Bulbs
1. Bulb Type:
H1, H3 ,H4, H7, H8, H9, H10, H11, H13, HB1, HB2, HB3, HB4, HB5
9003, 9004, 9005, 9006, 9007, 9008, 9140, 9145,
880, 881, 886, 889, 893, 894, 897, 898, 899 (all 800 series available)
D2S, D2R, D2C-D2S, D2R, D2C kits require a wiring harness that is sold separately
2. Color temperature: from 4300K, 5000K, 6000K, 8000K, 10000K, 12000K, 15000K, to 30000K
The folleing tests are carried out before delivery:
1) 6 hours continous working aging test
2) Connection circuit protection test
3) Over voltage protection test
4) Flash light concussion test
5) Quakeproof capability test
6) Cold, warm boot test
7) Polarity protection test
8) Short and circuit protection test
9) EMC anti-jamming test
10)Ballast and bulb matching test