Min. Order: | 1 Set/Sets |
---|---|
Place of Origin: | Hubei |
Location: | China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Electrical Plunger Voltage Regulator |
Model No.: | HRCJDY-BZ |
---|
HRCJDY-BZ Standard lightning impulse voltage pulse calibration test system devices | ||
The standard calibration verification test system device consists of : a standard impulse voltage meter , standard impulse voltage divider , oscilloscopes, computer records and test measurement and analysis software accessories. Calibration verification test is to identify lightning impulse voltage generator , lightning impulse voltage generator , single and continuous pulse voltage generator , lightning surge generator , lightning impulse current generator , lightning impulse current generator , single and continuous pulse current generator , lightning impulse withstand voltage tester for other areas of industry professionals , the lightning impulse flow resistance tester , pulse-pounding pressure tester , impact -resistant pulsed flow tester and other types of electronic pulse generator charging voltage , etc. and the output voltage or current accuracy level of accuracy , or the partial pressure ratio of the flow ratio of the detection range of the calibration and error detecting means detects the calibration standard . In August 19, 1994 , I was the first in China to detect lightning impulse impact test calibration device and starting to develop and produce a successful submission metrological traceability Chinese national high voltage metering station , lightning impulse measurement identification verification testing disposable success --- Get calibration report ! The standard calibration verification test system devices: small individual monomer units are portable , lightweight , modular , stable and reproducible, anti-interference ability , adaptability field use , anytime, anywhere can create a standard school composition test test test system calibration calibration. | ||
HRHG-23B Standard lightning impulse voltage meter peak | ||
HRHG-23B Standard lightning impulse voltage meter peak impact : the first is to measure any wavelength longer than 500ns single full-wave lightning impulse voltage can also be measured and stored lightning impulse voltage spikes , lightning impulse current peak as well as other one-time lightning pulse peak and continuous pulse peak , lightning surge peak operating wave peaks , steep peaks spread chopper intelligent special instrument , is the use of a more severe test conditions for the high-voltage test site specially developed . The overall design using standard industrial control bus special wiring . In the design of the shield machine , filtering and overvoltage protection circuit can be highly effective electromagnetic interference shielding . Range of the instrument can automatically switch features can be translated to the high side voltage divider ratio dial , you can read and display lightning direct digital pulse-pounding real value of output voltage or current generator . Portable . Input voltage : ≤ ± 1600V ( lightning impulse voltage pulse ) Input impedance : 2MΩ / / 40pF Accuracy : ± 1.0% Rise time : about 85ns Working environment : -25 ~ +55 ℃, 0 ~ 95% Divider ratio setting: 0.1 to 9999.9 Display range : 0 ~ 16000kV Connection : two parallel input socket Input Power : AC 220V 50Hz ± 10% Shape and size : length 518 × 168 × 438 high depth (mm); Weight :<5kg |