HFS Liquid Switches are Single-Pole-Double-Throw(SPDT) flow switches that are used in liquid lines carrying water, ethylene glycol, or other liquid not classified as hazardous. They can be wired to energize one device or powered from the same source when liquid flow either exceeds or drops below the set flow rate.
1.The rate of the flow can be adjustable and it is stable
2.Liquid temperature range: 0℃~+100℃
3.Max. Working Pressure: 13.5bar
4.Flow switch can not be used where the liquid in the pipes will drop below the liquid's freezing point
Descriptions |
Product | HFS Flow Switch | Maximum Liquid Pressure | 150psig()1034kpa | Minimum Liquid Temperature | 32oF(16℃) | Maximum Liquid Temperature | 250oF(121℃) | Electrical Ratings | 120VAC | 208VAC | 240VAC | 277VAC | Horsepower | 1 | 1 | 1 | - | Full Load Current | 16.0 | 8.8 | 8.8 | - | Locked Rotor Current | 96 | 52.8 | 48 | - | Non-inductive Current | 16.0 | 16.0 | 16.0 | - | Pilot Duty | 125VA at 24/277VAC | Wiring Connection | Screw Type Terminals | Pipe Connector | 1",1.5" NPT Threads |
|
|
Type | Connection size | Range of required to actuate switch (L/min) | Min. flow | Max. flow | Decrease of flow | Increase of flow | Decrease of flow | Increase of flow | HFS-25 | 1 | 18 | 21 | 45 | 50 | 1-1/2 | 30 | 35 | 100 | 105 | 2 | 50 | 58 | 150 | 155 | 2-1/2 | 75 | 86 | 187 | 200 | 3 | 100 | 115 | 225 | 260 |
|