user login

Indoor 2 pairs DP box for STB module, snap locking

Min. Order: 1000 Piece/Pieces
Payment Terms: L/C, T/T, WU
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Service
Main Products: Steel Tube PLC Fiber Splitter, VX Module, Copper Cabinet, LSA Disconnection Module, Optical Distribution Frame

Product Detail

Model No.: TP-1711-2
Means of Transport: Ocean, Air, Courier, Land
Brand Name: TAEPO / OEM / Netrual
Category: Copper communications
Material: ABS
Capacity: with 2pcs STB module or without
Packing: 1pcs/inner box + carton
Delivery Date: 7-14 days
Show

Product Description

Indoor 2 pairs DP box for STB module, snap locking
Indoor 2 pairs DP box for STB module, snap locking

Order Data
ITEM NOUNITDESCRIPTIONS
TP-1711-2pcsIndoor 2 pairs DP box for STB module, 105 x 65 x 60mm, snap locking, without STBmodule

Main Features
Made of highly impact resistant PC
Flammability according to UL 94 FV0
Smallest distribution box designed for outdoors
Easy operation and wide range of wire

Technical Parameters
1) Contact resistance between conductor and contact: under normal ambient conditions, the contact resistance between contacts ≤3 mΩ. After high temperature test, low temperature test, temperature varing test and humidity heat test, the increasing resistance ≤2 mΩ. And after terminating for 200 times, the increasing resistance ≤2 mΩ.
2) Dielectric strength: under normal ambient conditions, after high temperature test, low temperature test, temperature varing test and humidity heat test, the insulation resistance between any two independent contacts, and/or between contacts and metal parts is able to withstand an AC voltage of of 1000V (virtual value) at 45Hz~60Hz sinowave for 1 minute, without spark over and flying arc
3) Gas tight performance: contact touches the conductor at both sides, and thus forming the gas tight area, while the area of gas tight occupies ≥50% of the touched area on each side.
4) Conductor diameter range: 0.4mm-1.05mm, while insulation ≤ 5mm
5) Pulling strength:≥25N while pulling from the vertical side of the contacts
6) Flame retardant performance: all plastic parts are flame retardant, reaching grade of UL FV0
7) Life circle: ≥200 times
 
Post Buying Request