Min. Order: | 2000 Piece/Pieces |
---|---|
Trade Term: | FOB |
Payment Terms: | L/C, T/T, WU |
Supply Ability: | A large number of |
Place of Origin: | Zhejiang |
Location: | Ningbo, Zhejiang, China (Mainland) |
---|---|
Business Type: | Manufacturer, Service |
Main Products: | Steel Tube PLC Fiber Splitter, VX Module, Copper Cabinet, LSA Disconnection Module, Optical Distribution Frame |
Model No.: | TP-1501-1BGP |
---|---|
Means of Transport: | Ocean, Air, Courier, Land |
Brand Name: | TAEPO / OEM / Neutral |
Category: | Copper communications |
Material: | ABS with PCB |
Dimension: | 50x11.5x9.6mm |
Net weight: | 10g |
Color: | Light grey |
Capaicty: | 1 pair |
Funciton: | For LSA module |
Working temperature: | -20℃ - 60℃ |
Storage temperature: | -40℃ - 80℃ |
Relative humidity: | ≤85% (+30℃) |
Production Capacity: | A large number of |
Packing: | inner box + carton |
Delivery Date: | 7-14 days |
1 pair MDF protector for LSA module against over-voltage over-current
Order DataITEM NO UNIT DESCRIPTIONS TP-1501-1BGP pcs 1 pair MDF protector for LSA module # TP-1201-10/10P/8/5, against over-voltage over-current
ITEM NO | UNIT | DESCRIPTIONS |
TP-1501-1AGP | pcs | 1 pair MDF protector for LSA module # TP-1201-10/10P/8/5, against over-voltage over-current |
TP-1501-1BG | pcs | 1 pair MDF protector for LSA module # TP-1201-10/10P/8/5, against over-voltage |
TP-1501-1BGP | pcs | 1 pair MDF protector for LSA module # TP-1201-10/10P/8/5, against over-voltage over-current |
TP-1501-1CGP | pcs | 1 pair MDF protector for LSA module # TP-1201-10/10P/8/5, against over-voltage over-current |
Techinical Paramters
1) Working temperature: -20℃ ~ 60℃
2) Storage temperature: -40℃ ~80℃
3) Relative humidity: ≤85%(+30℃)
4) Atmospheric pressure: 70kPa ~106kPa
5) Appearance: the color of all metal and plastic parts is uniform, without any scratch, rust, crusting and cracks.
6) The labels are clear and complete.
7) Flame retardant performance: all plastic parts and printed circuit board are flame retardant, reaching grade of GB/T5169.7FV-0
8) Nominal DC spark-over voltage (100V/s) : 230±20% V
9) Impulse spark-over voltage (1kV/us): ≤700V
10) Impulse discharge current (8/20us, 10 times) (a+b)-e: 5kA
11) Impulse discharge current (10/1000us, 300times) (a+b-e):100A
12) AC discharge current (50Hz, 1s, 10 times) )(a+b)-e:5A
13) Capacitance(1kHz): ≤1.5 pF
14) Transverse voltage duration: ≤200ns
15) Fail-safe response time: ≤15s
16) Insulation resistance: insulation between line a and line b, and/or between line a, b and grounding wire and alarming signal line, and/or between grounding wire and alarming signal line ≥ 1000MΩ. And after high temperature test, low temperature test, temperature varing test and humidity heat test, the insulation resistance ≥ 1000MΩ.
17) Contact resistance: under normal ambient conditions, the contact resistance between protector and block contacts ≤7 mΩ. After high temperature test, low temperature test, temperature varing test and humidity heat test, the increasing resistance ≤3 mΩ And after inserting the connection cord (or test cord) into the module for 200 times, the increasing resistance ≤3 mΩ
Related product for 1 pair MDF protector for LSA module against over-voltage over-current
Related product for 1 pair MDF protector for LSA module against over-voltage over-current