Product explanation:
This tester is a integrated tester for plug. It is used to test the continuity, polarity, insulation, high-volt, leakage current of power plug. It meets the requirements of many international standards such as BIS, UL, CSA, VDE, BSI, DIN, CCC, IEC, etc. It is a totally automatic testing machine makes your operation more convenient and simple.
Features:
* All of the test subjects will done automatically.
* The inner/outer high-volt output value and persistence period can be adjusted separately.
* Test speed is quick, all test subjects will be achieved less than 2 seconds.
* The PLC control system comes from Mitsubishi. Made In Japan.
* The relay comes from Schneider. Made In French.
* If the specimen is incompetent, there is a alarm by buzzer and light.
* If the specimen is incompetent, this machine will stop at once and show you which subject is incompetent. Until you push the emergency button it will restart a new test. And a switch with key can be made to order to replace the high-volt starting button, it is very useful, because when a alarm happen, the operators can not restart this machine, only after managers have checked over and restart it by the key the machine will work again.
* When test over, the specimen will be pushed out automatically, and a "●" or other characters could be marked on it(English characters only).
Technical parameter:
Polarity test | Test E,L,N wires in sequence |
Insulation test high-volt | DC 500V +- 10% |
Insulation resistance | 2,7,20,50,100MΩ(can be made to order) |
Inner high-volt | 0~5KV +-5% (adjustable) |
Outer high-volt | 0~5KV +-5% (adjustable) |
Leakage current | 0.5,1,3,5,10mA(can be made to order) |
Rated power | 500VA |
Cylinder power | compressed air with 0.4 to 0.6Mpa |
Dimensions | 675mm W,480mm D,520mm H |
Power source | AC 220V +-10%,50Hz |
Weight | 35 kg, approximate |
NOTICE:
1,Inner high-volt is applied between L,N,E wires,and the outer high-volt is applied between L,N,E wires and jacket.
2,Both 3-wire and 2-wire power plug can be tested by this machine.
Test Objects:
Power Plugs