Place of Origin: | Fujian |
---|
Location: | Xiamen, Fujian, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Mainstream Sidestream Capnography Sensor
Complete model: Compatible with equipment from many well-known manufacturers around the world, with wide compatibility;
Using medical TPU plastic and low impedance wire: It has the advantages of good texture, bending resistance, corrosion resistance, and stable waveform;
Gold-plated nickel-plated equipment end connection hardware and electrode surface: Excellent electrical conductivity, ensuring full contact and reliable connection;
Using imported electronic components: It has the advantages of accurate value and stable waveform.
Specification of Side Stream Capnography Sensor
Project | Specifications |
Principle of Operation | Non-dispersive infrared(NDIR) single beam optics, dual wavelength, no moving parts. |
Initialization Time | Capnogram displayed in less than 3 seconds, full specifications within 3 minutes(At 25°C) |
CO2 Measurement Range | 0 - 114 mmHg; 0 - 15 %; 0 - 15.2 kPa |
CO2 Rise Time | Rise Time Less than 80 ms |
CO2 Resolution | 0.1mmHg 0 to 38 mmHg. |
0.25 mmHg 39 to 114mmHg. | |
CO2 Accuracy | 0 - 40mmHg ±2 mmHg. |
41 - 76mmHg ±5% of reading. | |
77 - 114 mmHg ±8% of reading. | |
Above 80 breaths per minute ±12% of reading. | |
* Note: Gas temperature at 25°C. | |
CO2 Stability | Short term drift: Drift over four hours shall not exceed 1 mmHg maximum. |
Long term drift: Accuracy specification will be maintained over a 120-hour period. | |
Sampling Frequency | 100Hz. |
Respiration Rate Range | 3 to 150 breaths per minute. |
Respiration Rate Accuracy | ±1 breath. |
Temperature | Operating: 0 to 40°C; Storage: -40 to 70°C; Transport: -40 to 70°C. |
Humidity | Operating: 10 to 90% RH, non-condensing; Storage: 10 to 90% RH, non-condensing. Transport: 10 to 90% RH, non-condensing. |
Atmospheric Pressure | Operating: 400-800 mmHg; Storage: 400-800 mmHg; Transport: 400-800 mmHg. |
Water Resistance | IPX4 - Splash-proof - Sensor only. |
Sensor Weight | <250g |
Sensor Size | Deep*Wide*High: 102mm*62mm*38mm |
Cable Length | 0.75m |
Details of Sidestream Capnography Sensor
Quick Details of Sidestream Capnography Sensor
Designed for use with monitors and ventilators equipped with a carbon dioxide function, it accurately and swiftly collects end-tidal carbon dioxide values and generates visual curves. Both reusable and disposable consumables are available.
If you want to know more kinds of sidestream capnometer, please visit our website.
Now the price of capnography monitor for sale is reasonable, anything you need, please contact us.