Conductor Material: | Aluminum |
Jacket: | Others |
Insulation Material: | XLPE |
Type: | Low Voltage |
Brand Name: | Qingzhou |
application: | overhead distribution systems |
Conductor: | Aluminium conductor, round stranded compressed (RM) |
Insulation: | XPLE compound, UV-resistant, PE |
sample: | free |
Production Capacity: | 100000 |
Packing: | wooden drum |
Delivery Date: | 30days |
APPLICATION
Aerial Bundled Conductor cables can be used to replace bare conductor cables in overhead distribution systems. It is ideal for use in urban areas with congested power distribution and narrow lanes and by-lanes. The flexible system is much easier than conventional overhead power lines to re-route when demanded by changes in urban development plans.
CONSTRUCTION
ABC (Aerial Bundled Cables or Aerial Bundled Conductors) are several phase conductors insulated and tightly bundled together with bare neutral conductor for use in overhead power lines. It utilizes the same principles as used for bundled conductors, but are much closer together and each one, except the neutral line, is surrounded by a layer of insulation. This is in direct contrast to the traditional use of uninsulated conductors which are separated by air gaps. LV (Low Voltage) abc aluminum cable are already in use in many countries around the world.
STANDARDS
Basic design to AS/NZS 3560-1 / BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 standards.
APPLICATION
Aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders to residential premises.
Standards
Basic design to IEC 60502 / AS/NZS 3599-1 standards.
CONSTRUCTION
Phase Conductor: Circular compacted stranded H68 aluminium to BS2627.
Conductor Screen: Extruded semi-conductive layer.
Insulation: XLPE
Insulation Screen: Extruded semi-conductive layer.
Metallic Screen(optional): Copper wire screen or copper tape screen.
Separator: Semi-conductive swellable tape.
Outer Sheath: HDPE
Support Conductor: Galvanized steel wires.
Assembly: Three XLPE insulated screened cores are bundled around the galvanized steel wires in a right hand lay.
0.6/1 KV ABC-Aerial Bundle Cable- IEC 60502 & TNB-(AL/PE)
Number of cores x nominal cross section | min. breaking load of conductor strand | Current rating in the air | Outer diameter | Total weight |
mm^2 | kN | A | mm | kg/km |
1x16+1x 25 RM | 6.4 | 61 | 15.3 | 160 |
3x16+1x 25 RM | 6.4 | 61 | 19 | 290 |
3x25+1x 25 RM | 6.4 | 84 | 23.2 | 400 |
3x35+1x 25 RM | 6.4 | 104 | 25.6 | 500 |
3x50+1x 35 RM | 8.9 | 129 | 30 | 680 |
3x70+1x 50 RM | 12.1 | 167 | 34.9 | 920 |
3x95+1x 70 RM | 18 | 209 | 40.6 | 1270 |
3x120+1x 70 RM | 18 | 246 | 44.1 | 1510 |
3x150+1x 95 RM | 24.2 | 283 | 49.2 | 1870 |
3x185+1x120 RM | 30.8 | 332 | 54.9 | 2340 |
3x25+1x25+1x16 RM | 6.4 | 84 | 23.2 | 470 |
3x35+1x25+1x16 RM | 6.4 | 104 | 25.6 | 560 |
3x50+1x35+1x16 RM | 8.9 | 129 | 30 | 740 |
3x70+1x50+1x16 RM | 12.1 | 167 | 34.9 | 980 |
3x95+1x70+1x16 RM | 18 | 209 | 40.6 | 1330 |
3x120+1x70+1x16 RM | 18 | 246 | 44.1 | 1580 |
3x150+1x95+1x16 RM | 24.2 | 283 | 49.2 | 1940 |
3x185+1x120+1x16 RM | 30.8 | 332 | 54.9 | 2410 |