Min. Order: | 1 Set/Sets |
---|---|
Payment Terms: | Paypal, L/C, D/P, D/A, T/T, WU, Money Gram |
Supply Ability: | 1000 |
Place of Origin: | Shandong |
Location: | Qingdao, Shandong, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company, Agent |
Model No.: | JC-YZ-600 |
---|---|
Means of Transport: | Ocean, Air, Land |
Product name: | Atomic Absorption Spectrophotometer |
brand: | juchuang |
wavelength range: | 185nm-910nm automatic adjustment |
Grating line density: | 1800 lines/mm |
Monochromator: | Aberration Czerny-Turner Monochromator |
Wavelength accuracy: | ±0.10nm |
wavelength repeatability: | ≤0.05nm |
Production Capacity: | 1000 |
Product introduction
1. Optical system
wavelength range | 185nm—910nm automatic adjustment |
Grating line density | 1800 lines/mm |
Monochromator | Aberration Czerny-Turner Monochromator |
Spectral bandwidth | 0.1, 0.2, 0.4, 1.0, 2.0nm, multi-speed automatic switching |
Wavelength accuracy | ±0.10nm |
wavelength repeatability | ≤0.05nm |
baseline drift | Static ±0.002A/30min Dynamic ±0.006 A/30min |
Detector | Wide spectral range photomultiplier tube |
Resolution | To distinguish 279.5nm and 279.8nm double lines of manganese lamps , the valley energy between the two spectral lines should be less than 20% |
2. Light source system
lamp holder | 8 lamp holder automatic switching |
Lamp power supply mode | 400Hz square wave pulse |
Lamp current adjustment range | 2 — 10mA average current |
3. Atomic system
flame analysis method | |
Detection limit (Cu) | <0.003μg/ml |
Characteristic concentration (Cu) | <0.015μg/ml/1% |
burner | 100mm full titanium burner |
Precision | RSD<0.5% |
sprayer | Metal Sleeve High Efficiency Glass Sprayer |
spray chamber | Corrosion-resistant all-plastic spray chamber |
safety measures | With a variety of automatic safety protection functions: acetylene leakage alarm, automatic shutdown system, etc. |
Flameless (graphite furnace) analytical method | |
Detection limit ( Cd) | <0.4*10ˉ12g |
Feature quantity ( Cd) | <0.5*10ˉ12 g |
Hydride Generation - Atomic Absorption |
4. Flame analysis method
Measurement methods | Air -acetylene flame method |
Concentration calculation method | Standard curve method, standard addition method, interpolation method. |
Repeat measurement times | From 1 to 99 times, the average value, content, standard deviation and relative standard deviation are automatically calculated. |
result print | Print test data or final analysis report. The results can be exported to a word worksheet. |
Software Environment | Windows XP/ Windows 7 operating system, Chinese professional software |
5. Flameless (graphite furnace) analysis method
Measurement methods | Graphite furnace peak height method, graphite furnace peak area method |
Concentration calculation method | Standard curve method, standard addition method, interpolation method. |
background correction | Deuterium lamp background correction is greater than 60 times, and self-absorption deduction background is greater than 60 times |
Repeat measurement times | 1-30 times, calculate the mean, give the standard deviation and relative standard deviation |
result print | Print test data or final analysis report. The results can be exported to a word worksheet. |
Software Environment | Windows XP/ Windows 7 operating system, Chinese professional software |
2. Product parameters
power supply | AC 220V/50HZ |
power | 150VA |
Instrument net weight | 55kg |
Instrument gross weight | 80kg |
Instrument volume | 1110mm (horizontal) × 400mm (depth) × 500mm (height) |
package volume | 1350mm (horizontal) × 600mm (depth) × 850mm (height) |
Working temperature | 10~35℃ |
Working environment humidity | ≤80% |
3. Product Features
1. Total reflection optical system, full-band achromatic, automatic wavelength scanning and automatic peak finding. 2. With deuterium lamp button background, self-priming button background. 3. The uniquely designed all-titanium burner has smooth combustion and fast heat balance. 4. Automatic adjustment of negative high voltage, lamp current, automatic adjustment of the best element lamp position, automatic ignition, automatic flameout protection. 8 lamp stands (optional 2 high-performance lamps) automatic control system, which can adjust the hollow cathode lamp to the best position in all directions, can set the lamp position of a specific element independently, and can freely set the working lamp, preheating The lamp saves the element lamp preparation time to the greatest extent possible. 5. Graphite furnace heating: users can freely set the heating curve according to their needs. Advanced graphite furnace constant power temperature control design: the temperature of the graphite tube is uniform and consistent, and the working temperature of the graphite tube maintains a good dynamic stability to ensure the accuracy of the analysis.