The charger is compatible with either type 1 or type 2 cable, it is available for 7KW and 22KW.
Compliant with the industrial standards, the charger has built-in RCD and branch breaker to secure safety. The charger also includes 6mA DC leakage detection, which eliminates the need for an expensive up cost of RCD type B.
The charger can be connected to a charging network with the help of build-in communication module through 4G/WIFI/Ethernet. Thanks to open charge protocol OCPP 1.6, the charger operation and status is monitored and controlled by existing backend or central management system.
Innovativeness
Temper glass panel, slim design.
Intelligent Control
Wireless communication (Wi-Fi/Bluetooth), Ethernet/4G optional OCPP communication protocol with CMS
Adjustable current
16A or 32A adjustable output current
Flexible Option
Universal Type 2 socket, optional with Type 1/Type 2 charging cable APP operation or RFID authentication or plug and play Wall-mount or floor-stand installation
Secure and Safe
RCD Type A residual current protection
Specification | Model | AC7000-MW132ED | Model | AC022K-MW332 |
AC Power Input Rating | IEC standard | IEC standard |
1-phase | 3-phase |
220V±15% | 380V±15% |
AC Power Output Rating | 7kW / 32A | 22kW / 32A |
Rated Frequency | 50/60Hz | 50/60Hz |
Required Service Panel Breaker | Dedicated Dual Pole | Dedicated 3-Pole |
(Build-in Branch Breaker) | 40A (32A station) | 40A (32A station) |
Power Wiring | 3 Wire - Live, Neutral plus PE | 5 Wire-L1,L2,L3, Neutral plus PE |
Connector Type | IEC 62196-2 (Type 2) | IEC 62196-2 (Type 2) |
Connector Mechanical Operating Life | ≥10000 times | ≥10000 times |
Charging Cable Length | 5m or Customize Length | 5m or Customize Length |
Charging Control | Plug and Play, RFID Card or App |
Display Screen | 4.3-inch LCD Screen |
External Communication | LAN (RJ-45) and Wi-Fi |
OCPP Protocol (Optional) | 1.6 or 2.0.1 |
Energy Meter | No |
Voice Prompt (Optional) | Voice guide of the charging process in English |
Indicators | 4 LED indicators-Power/Connect/Charging/Fault |
Storage Temperature | -40 to 75℃ (-40 to 167℉) ambient |
Operating Temperature | -30 to 55℃ (-22 to 131℉) ambient |
Operating Humidity | Up to 95% non-condensing |
Altitude | ≤2000m |
Cooling Method | Natural Cooling |
RCD | Type B |
Protection Ratings | IP 65 |
Over Voltage Protection | Yes |
Over Load Protection | Yes |
Earth Leakage Protection | Yes |
Over-temp Protection | Yes |
Under Voltage Protection | Yes |
Short Circuit Protection | Yes |
Ground Protection | Yes |
Surge Protection | Yes |
Dimension (H×W×D, mm) | 410×260×164 |
Weight | 1-phase<10kg; 3-phase<12kg |
Enclosure Material | Front-Panel: Tempered Glass; Back-cover: Metal Plate |
Dimension (H×W×D, mm) | 1400×200×100 |
Weight | <8kg |
Enclosure Material | Metal |