user login

ASTM D1230&NFPA 702 45 ° Flammability of Wearing Apparel Apparatus CA TB 117

1.0 USD
Min. Order: 1 Set/Sets
Trade Term: FOB,CFR,CIF,DAT,FAS,DDP,DAP,CIP,CPT,FCA,EXW
Payment Terms: L/C, T/T, WU
Supply Ability: 20 sets per month
Place of Origin: Jiangsu

Company Profile

Location: Suzhou, Jiangsu, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: AIC-1230
Power: Electronic
Usage: Others
Brand Name: AI
Test standard: ASTM D1230,NFPA 702,CA TB 117
Power supply: AC 220V,50/60Hz,5A
Size: 750*300*900 mm³
Color: white
Warranty: 1 Year
Production Capacity: 20 sets per month
Packing: Plywood case
Delivery Date: 30 days
Show

Product Description

45 ° Flammability of Wearing Apparel Apparatus

Introduction

This 45 ° Flammability Apparatus is designed according to the latest edition of the national standard GB/T14645 design and manufacturing.It applies to textile fabric in under 45 ° combustion, determination of the damaged area and damage length determination of heat or melt number to provide exposure to the flame length. Combustion evaluation of refractory materials fire-resistant and can be based on compliance with the implementation of standards, measurement of sampleis installed at a45 degreeangle light and perfect combustion combustion characteristics.

45 degree flammability apparatus is used for measuring burning time and passive smoke glow time, graphic placement sample received someradiation,and fixed heat generated in the Chamber.

Standards
• ASTM D 1230:
• NFPA 702:
• CA TB 117 (2000):

Main Features:
Structure parts:
1, Test box is painted treatment, beautiful, corrosion-resistant;
2, Heat-resistant glass window easy to observe internal test status;
3, Internal tooling materials are made of stainless steel;
4, Power switch and start switch;
5, Tank top and side of the box have six air vents;
6, Do different experiments to replacesampleholder;
7, The sample holder should be replaced when doing different experimental;
8, Japan importedflowcontrol valve, precise control of the flame height;
9, Imported brands gauge and pressure regulator valve;

Damaged area of the test section:
• Needle valve adjust flame height to 45 ± 2m;
• Complete combustion time: The counter display glow time, resolution 0.1s;
• Glow time:Thecounter display complete combustion time, resolution 0.1s;
• Flame spread time: The set time of sample ignition (flame spread time);
• The counter is set to "0" reset switch;
• Temperature display range and accuracy: 0 ~ 90 ± 1 ºC;
• Imported brands gauge and pressure regulator, gas pressure can be displayed;
• Complete combustion stop switches;
• Planimeter is optional.

Specification

1Power supplyAC 220V,50/60Hz,5A
2Size750*300*900 mm³
3Weight30KG
4Flame height scaleOne
5Sample holderOne
6AuxiliariesVacuum cleanners,propane

Post Buying Request