EN ISO 1716 Bomb Calorimeter for Building Products
I. Introduction:
1. The bomb calorimeter automatically records the data of temperature and time.
2.Based on the input heat capacity, sample quality and additional heat and related data, it can automatically fulfil temperature correction and gross heat of combustion calculation, and give the results.
3.Gross heat of combustion and net heat of combustion can read directly,without calculation;
4.The outer barrel is dual layers cylinder with insulation cover.The insulation material is filled between inner and outer walls.The inner cylinder is made of polished metal,in which the bomb vessel can totally immerse.And it has automatic water injection device,which can supply water if being lack of water during test.The volume is 2200mL.
5. This equipment is supplied with PC and device for making the "cigarette"
6. The computer of the bomb calorimeter has the icon display function, display curve, Excel spreadsheets, print function, data input, command and control functions.In order to perfect the system, the computer system can be added to fault alarm, warning, alarm, etc.
7. It contains crucible method and cigarette method;
8.The stirrer is drove by constant motor,avoiding heat transmission of calorimeter.And insulation pad is added at the contacting part of stirring shaft.
9.The temperature measuring device adopts OMEGA PT100 sensor.
II.TechnicalSpecifications:
S.N. | Item | Parameter |
1 | Gross heat of combustion | 0.01MJ / kg ~ 30MJ / kg |
2 | Repeatability error | Dynamic ≤0.1% |
3 | Temperature range | 0 ~ 50 ℃ |
4 | Temperature resolution | 0.0001 ℃, using PT100 sensor |
5 | Volume of bomb vessel | 300±50ML,mass:3.25KG |
6 | Supply pressure | 0 ~ 3.5Mpa without leakage |
7 | Pressure resistance | ≥21Mpa pressure |
8 | Ignition circuit | 12V,adjustable current 100mA,firing wire diameter 0.1mm |
9 | Stirrer power | 3W |
10 | Stirrer vessel speed | 375r / min |
11 | Power supply | AC 185~245V |