user login

BS 476-6 Fire Spread Index Tester for Fire Spread Test of Building Materials

1.0 USD
Min. Order: 1 Set/Sets
Payment Terms: L/C, T/T, WU
Place of Origin: Jiangsu

Company Profile

Location: Suzhou, Jiangsu, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: FPT
Power: Electronic
Usage: Others
Brand Name: AI
Test standard: BS476-6 Fire spread Index Test
Gas supplies: G112, as specified in BS 4947
Weight: 46kg
Color: White
power supply: 230 volts Nominal 10 Amps
Warranty: 1 Year
Packing: Plywood case
Delivery Date: 60 days
Show

Product Description

BS 476-6 Fire Spread Index Tester

INTRODUCTION

BS 476 part 6 specifies a method of test, the result being expressed as a fire spread index, that provides a comparative measure of the contribution to the growth of fire made by an essentially flat material, composite or assembly. It is primarily intended for the assessment of the performance of internal wall and ceiling linings.

FEATURE


  • Stainless steel support frame andCalcium silicate board combustion chamber.

  • Three kinds of sample holders for different thickness of the specimens.

  • Low reflective black finished mild steel Chimney and Cowl assembly complete with thermocouple mounting points.

  • Compliant stainless steel gas burner.

  • Two K type mineral insulated thermocouples complete with ceramic insulators.

  • Two pencil type heaters with 1000w installed in combustion chamber.

  • Control gas instrumentation including electronic gas on/off valve, flow regulating valve, flow meter and manometer.

  • Intelligent single phase power controller with feedback loop for accurate control of electric heating elements

  • DAQ record automatically the mV output from the thermocouples of the flue gas throughout the duration of the test.

  • According to the test time, automatically adjust the output power.


  • Data Acquisition system:


  • Prompted software interface

  • Data recording and display of cowl temperature against time

  • Data recording and display of ambient temperature against time

  • Display of power value in kW

  • Calibration routine

  • Calculation of output rise and calibration value


  • Installation requirements

    Electrical230 volts Nominal 10 Amps
    Ambient Temperature10°C to 35°C
    Gas suppliesThe gas supply specified in the Standard is Standard test gas G112, as specified in BS 4947
    FlowGas flow for burner adjustable from 0 to 5 nl/min
    Pressure1KPa
    Dimensions

    Apparatus: 400mm (W) x 600mm x (H) x 300mm (D)

    Control module: 400mm (W) x 500mm x (H) x 400mm (D)

    Weight46KG
    Applicable standardsBS476-6


Post Buying Request