user login

Full Automatic Temperature Rise Test System

Min. Order: 1 Set/Sets
Trade Term: FOB,
Payment Terms: T/T
Supply Ability: 10
Place of Origin: Hubei

Company Profile

Location: Wuhan, Hubei, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: TKDL-WS
Input Voltage: AC380
Production Capacity: 10

Product Description

Product Introduction


TKDL-WS  automatic temperature rise test system is used for manufacturers testing the high and low voltage electrical products before delivery. It provides two functions of large current and temperature test. Convenient for user operation improves working efficiency. It applies to power plant power distribution station electrical appliance manufacturing factories scientific researching institutes laboratory. Multi channel temperature recorder uses digital synchronous sampling technology with advantages of rapid test speed high precision convenient to operate good appearance.


 

product features Product Characteristics


1,This product is composed of large current generator voltage regulator temperature tester industrial controlling computer operation system.

2,Voltage and current displayed by industrial controlling computer software precision level is 0.5.

3,With zero position starting up protection function and emergency stop function.

4,Software test time self setting and with prompting function.

5,After current setting any deviation software can automatically adjust according to the parameters set in advance.

6,Prevent strong magnetic interference.

7,Use imported K type thermocouple: 0~1370℃.

8,Temperature tester with multi channel temperature monitoring measuring recording function and comparing with the test point             temperature formrising temperature self alarm when the rising temperature higher than setting temperature. Any point temperatures and temperature rising value can be checked measurement error is ±1%.

9,Adopt anti interference technology combined with the hardware and software function is stable and anti-interference is strong. Four basic screens digital display picture bar chart display picture real time curve picture recall curve picture.

Product Parameters

Technical Parameters

 The Main Technical Parameters

Input Voltage

AC380    Three-phase four-wire AC380

Rated Frequency

50 Hz

Total System Power

189KW

Total System Current

287A

System Power Factor

Cosφ=0.8

Oil-immersed Induction Regulator

Dry Uplift

Rated capacitance

63KVA

Rated capacitance

63KVA

Output Voltage

0-430V

Output Voltage

10V

Output Current

0-166A

Output Current

0-6300A

Waveform Distortion

≤3%

Rated Input Voltage

380V

Starting Voltage

≤1%

Load Loss

<4%

Short-circuit Resistance

≤7%

Rated Input Current

166A

 



♦ Input voltage: 220V or 380V


♦ Output current:500~10000A

 

Model

Rated Capacity
(KVA)

Rated Input

Rated Output

Impendence Voltage
%

No-load Current
%

Structure

Regulator

Current Injector

Current(A)

Voltage(V)

Current(KA)

Voltage(V)

TKDL-WS 1.5/500

1.5

1.5

6.8

220

0.5

3

<8

<6

Compact

TKDL-WS 3/1000

3

3

13.60

220

0.5/1

6/3

<8

<6

Compact/Separate

TKDL-WS 6/2000

6

6

27.00

220

1/2

6/3

<8

<6

Separate

TKDL-WS 12/4000

12

12

37.50

400

2/4

6/3

<8

<6

Separate

TKDL-WS 15/5000

15

15

37.50

400

2.5/5

6/3

<8

<6

Separate

TKDL-WS 30/10000

30

30

75

400

5/10

6/3

<8

<6

Separate

TKDL-WS 45/15000

45

45

112.5

400

7.5/15

6/3

<8

<6



Post Buying Request