Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB, |
Payment Terms: | T/T |
Supply Ability: | 10 |
Place of Origin: | Hubei |
Location: | Wuhan, Hubei, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Model No.: | ZGF |
---|---|
Specifications: | 200/2 |
Production Capacity: | 10 |
Dc Hipot Test Equipment for the power supply department, for example: DC HV withstand and leakage current test in power cables, the conductance current and 1mA reference voltage of magnetic blow out arrester and zinc oxide arrester test.ZGF DC Hipot Test Equipment supplies 60kV to 400kV from 60kV to 400kV is DC high voltage power supply equipment.It has functions of switch on protection under 0 voltage,over voltage and over current protection.They are high stability and reliability. ZGF is easy to operate , small in size and light in weight.
1, Series dc high voltage generators have small ripple coefficient stable and reliable voltage output no noise and good reliability
2, with overvoltage overcurrent zero voltage start and fault protection voltage protection value can be set display intuitive
3, voltage current using digital display and power supply has a reading easy to monitor the output status
4, with 0.75 times voltage conversion easy to test zinc oxide arrester
5, the product structure is compact small size easy to carry
Specifications | 200/2 | 200/3 | 200/5 | 300/2 | 300/3 | 300/5 |
Rated current(mA) | 2 | 3 | 5 | 2 | 3 | 5 |
Control box quality(kg) | 5.5 | 6.0 | 6.5 | 6.5 | 6.5 | 7.5 |
Double cylinder height(mm) | 970 | 970 | 970 | 1250 | 1250 | 1250 |
Voltage accuracy | ±(1.0%Reading + 2 words) | |||||
Current accuracy | ±(1.0%Reading + 2 words) | |||||
Ripple coefficient | ≤0.5% | |||||
Voltage stability | When the power supply voltage changes by ±10%≤1% | |||||
Overload capability | No-load voltage can exceed 10% of rated voltage for 10 minutes | |||||
The maximum charging current is 1.25 times the rated current | ||||||
power supply | Single phase communication 50Hz 220V±10% | |||||
Way of working | Intermittent use: rated load 30 minutes | |||||
1.1 times rated voltage usage: 10 minutes | ||||||
Way of working | temperature:-10℃~+40℃ | |||||
Relative humidity: no more than 85% at room temperature of 25 ° C (no condensation) | ||||||
Altitude: below 1500 meters | ||||||
With capacitive load capacity | The tested product has unlimited capacity | |||||
Charged with 1.5 times rated current | ||||||
Structural features | Electrical insulation doubler | |||||
Air insulation no leakage | ||||||
Operating box features | High-precision 0.75UDC1mA one-touch button (accuracy ≤1.0%) suitable for zinc oxide lightning arrester test | |||||
Overvoltage protection using digital dial switch at a glance | ||||||
Portable chassis more convenient on site |