Model No.: HF6000
Means of Transport: Ocean, Air
Type: Blood Analysis System
Channel: 2 and 4 channels
Principle: Photoelectric magnetic beads method
Printer: Built in printer
Warranty: 1 year
Preheat temperature: 37℃ ± 1℃
Language: English
Preheat timer: equipped with preheat timer system
Preheat time: 15-30 minutes
Display: 5.7 inches LCD screen
Production Capacity: 200 sets per month
Packing: packed in carton box
Delivery Date: within 5 days after receive the payment
Show

Product Description

              HLIFEK blood coagulation analyzer / Coagulometer price

Product Description:

HF6000-series semi-automatic coagulation analyzer (IVD) has two types:HF6000-2 (dual-channel), and HF6000-4 (four-channel). The analyzer has a bench-top design and is ideal for small and medium-sized hospitals,laboratories,and clinical centers.The measurement principle is photoelectric magnetic beads method,i.e.:using photoelectric to test movements of magnetic beads, in order to determine the freezing point of the blood,and measure the time of blood freezing.This method is free from the interference of Jaundice, Hemolytic, Chyle and other samples. It is easy to operate and highly accurate, with low consumption of reagents; this equipment is highly valued by its cost-effectiveness.

 

 

Technical Parameter:

Analysis methods

Photoelectric magnetic beads method,

free from the influence of jaundice, hemolysis, chyle, turbidity and bubble

Operation methods

Linkage and manual two ways to start the measurement, reduce manual error

Two type instruments

dual channels(HF6000-2),

four channels(HF6000-4)

4 channels instrument can conversion two modes by one button (four people with the same item/one people with four items)

Test items

Prothrombin Time (PT), Activated

Partial Thromboplastin Time( APTT),

Fibrinogen (FIB),Thrombin time (TT)

Preheat timer

equipped with preheat timer system, sound and light automatic prompt

The scope of detection

 the Fibrinogen has a wide detection scope, can detect any abnormal plasma which with the ultra-high or low fibrinogen levels

Preheat temperature

37℃ ± 1℃

Preheat time

15-30 minutes

Results saving automatically, real time reports and comprehensive reports printed

Compared with the optical method, the testing results with high accuracy and good repeatability

Power off protection

10000 records that can store as long as 10 years

Open reagent, small sample consumption

Display

5.7 inches reversible LCD screen

Voltage

AC 220V ± 22V, 50Hz±1Hz

Input voltage

≥170VA

Working temperature

10 ℃ - 30 ℃

Relative humidity

30% - 80 %

Dimension

490nm * 435nm * 280nm

Weight

7.5kg