Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB |
Payment Terms: | T/T, WU, Money Gram |
Supply Ability: | 5000sets/month |
Place of Origin: | Hubei |
Location: | Wuhan, Hubei, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Model No.: | BI50 |
---|---|
Means of Transport: | Ocean, Air, Land |
Brand Name: | CHIP |
Color: | white and blue |
Weight: | 4.3kg |
test time: | 10mins |
environment humidity: | 40% ~ 85% |
Frequency or frequency range: | 50-60Hz |
Production Capacity: | 5000sets/month |
Packing: | wooden box |
Delivery Date: | 5-15 work days after payment |
We are committed to the research and development and production of biochemical analyzer for nearly ten years, making its weight concentrated to 4.3kg and portable, and the inspection time is also concentrated to only 10 minutes, with accurate results
Automatic Biochemical Analyzer BI50
After adding the sample, it only takes about 10 minutes to complete the inspection and print the results automatically. The analyzer has a built-in intelligent quality control system. The results are accurate and can obtain the same accurate test results as those of the large third-class hospitals. Even if you learn, the small clinics can perform biochemical tests as quickly and easily as the large hospitals.
Technical Parameters
Volume: 27 cm (L) x 15.5 cm (W) x 36 cm (H)
Weight: 4.3 KG
Voltage: AC 100V-240V, 50Hz ± 1Hz
Ambient temperature: 15 ℃ ~ 30 ℃
environment humidity: 40% ~ 85%
Detection Indicator :Single sample and multiple indicators, 6 reagent combinations, 30 detection items
Data communication: Software upgrade function by WIFI, USB2.0, support LIS
Device category: Portable.
Sample type:Anti-coagulation whole blood, serum, plasma
Testing time 10mini
Storage >10000000 results
Printer built-in thermal printer and external printer
Animal types: Over10 species
Power supply voltage or voltage range: AC100-240V;
Frequency or frequency range: 50-60Hz;
Power or current rating: 2.0A
Our Advantages
1.High integration
High integration, small footprint, light weight, convenient for carrying around for testing.
2.Fast and stable
Add sample in 1 step and operate in 3 steps. The test results can be automatically printed in about 10 minutes, reducing customer waiting time and improving customer satisfaction.
3.Guarantee of results
The equipment software has a built-in real-time full-automatic quality monitoring system, and complete quality control of the equipment, reagents and specimens from the beginning to the end of each test, to ensure that the samples being checked have accurate test results, and the accuracy of later diagnosis and treatment .
4.After-sale warranty
Service is the top priority of an enterprise. In the process of using products, it constantly provides professional and fast after-sales service.
A. Simple operation, three steps in place
B. Quick results in 10 minutes
C. 7 inch HD color touch screen
D. Comes with thermal printing
E. Built-in quality control system
F. Test results are accurate and reliable
G.4.3kg light and portable body with small footprint
H. It can be connected to the hospital management system through the data interface to avoid secondary entry and help improve the work efficiency of operators.
I. Fully automatic detection, the system will automatically perform calibration before each detection.
Storage
The packaged analyzer should be stored in an ambient temperature of 0 ° C to 40 ° C, a relative humidity of not more than 85%, a non-corrosive gas, and a well-ventilated room.
Environmental conditions:
(1) Indoor / Outdoor use: Indoor use.
(2) Altitude: The altitude does not exceed 2000m.
(3) Ambient temperature: Operating temperature is 15 ℃ ~ 30 ℃.
(4) Ambient humidity under different temperature conditions: 40% to 85%, relative humidity (non-condensing).
(5) Power supply voltage fluctuation: not more than ± 10% of the nominal voltage.
(6) Transient overvoltage category: Impact resistance category II.
(7) Rated pollution degree: pollution degree 2.
(8)Away from strong electromagnetic field interference;
(9)Avoid direct sunlight
(10)Have a good grounding environment.
Biochemical analyzer operation steps:
Step 1: Add samples
Just collect 100ul of whole blood, serum or plasma and transfer it to your own reagent tray. The single-use single-use disc contains all the lyophilized reagents, dilutions, and calibration curves needed to perform a complete fixed multiplex test panel.
Step 2: Insert the disc
Follow the touch screen commands. Place the CD in the analyzer drawer and enter the required information. The rest of the steps are performed by the biochemical analyzer. In about 10 minutes, accurate results will be ready.
Step 3: Read the results
The complete panel results include patient demographic information, chemical concentration, reference range, sample integrity index and iQC can be displayed on the full color display, with thermal printing, or can be transferred to an external printer. Up to 99999999 patients and quality control results are stored on the board.
janneyhu AT whxinsheng.com.cn