Power Supply
Power Consumption
Protection Fuse
FS Signal Input
Excitation Voltage
Analog Signal Input
Analog Signal Sensitivity
Dielectric Strength (Input Impedance)
Internal Resolution
Non-Linearity
Zero Stability
Span Stability
Step Width Division
Zero Balance
A/D Conversion Rate
Conversion method
Display
Display resolution
Maximum capacity
Decimal places
Negative sign
Over-range
Tare Range
Keyboard
Working Temperature Range
Working Humidity
Communication Interface
Baud Rate
Print Interface
Relay Signal Output
Relay Contact Capacity
Hermetical Seal (IEC529)
Material Finish
Gross Weight
Outside Dimensions
Opening Dimensions
Mounting Dimensions
|
VAC
VDC
W
A
mV
VDC
mV
uV/d
uV/ ℃
ppm/ ℃
t/s
divisions
℃
Bit/s
way
kg
mm
mm
mm
|
110,220VAC, 50Hz ± 2%
6VDC
9W
1A
2~15 mV
5VDC, driving 12 off 700Ω Load Cells;
-1~+9 mV
0.2uV /d(min.), 1.5uV/d(recommend)
More than 100MΩ at 500VDC between
Common/Earth/Each Opto-coupler Output for 1 minute
24
≤ 0.01% FS
≤ 0.01
≤ 5
Selectable: 1, 2, 5, 10, 20 or 50
±4% FS ±10% FS ±20% FS ±50% FS
7.5 to 960
Delta-sigma
6 digits x 20mm RED LED,
300 to 10,000 divisions
500 to 100,000
Selectable of 4 places
"-" indication on the left most digit
"---H---" indication
0 to +100% FS
5 Function Keys
-10 to 70
≦ 90% RH, non-dew
RS232 and RS485
Selectable of 1200, 2400, 4800, 9600
Serial Port, Programmable Print Format
2 ways
28VDC, 2A; 220VAC, 1A;
IP66
Stainless Steel
0.8kg
180 x 130 x 80mm
......
M6 x 2 at ctc 100mm |
Parameter setting and calibration are done at the front panel
Auto Zero selectable when switching on indicator or from memory
Auto zero tracking
Units Selectable
Fault Indication and Alarm
Operation modes: Normal Weighing mode, Peak mode and Count mode
Zero Scale, Tare Mode, selectable of Gross/Net Weight
RS232C communication port for Continuous Data Transmit and Request Data Transmit
F.S. Selection
Peak Value Test
Battery Voltage Indication, Low voltage Power
Accumulated Weight Function |
|
yes
yes
yes
kg or lb
Fault Indication, Alarm when Mis-use
yes
yes
yes
yes
yes
no
yes |