Do you know what the short circuit impedance of transformer is?

Transformer such as the oil immersed transformer, it is an important electrical equipment, in the process of use to enhance the use of the transformer and efficiency of continuous improvement, because the voltage of the transformer is affected by many factors, the voltage control, use and adjust the pressure is not the same. The impedance of short circuit to transformer is also a main reason that affects transformer work, and it is also one of the most effective means to control voltage. Then in the actual operation and work, the transformer's short-circuit impedance is what mean, here we give you a detailed introduction:

Concept of A

In general, the short-circuit impedance of a transformer refers to the equivalent series impedance Zk=Rk+jXk between the terminals of a pair of windings at the rated frequency and the reference temperature. As its value is determined by load test in addition to calculation, it is customarily called short circuit voltage or impedance voltage.

Concept of B

Short-circuit impedance is a very important item in transformer performance index.

Influence of transformer short-circuit impedance on transformer operation:

Transformer short-circuit impedance is also called impedance voltage, in the transformer industry is defined as follows: when the transformer secondary winding short-circuit (steady state), the primary winding flow rated current and applied voltage is called impedance voltage Uz. Usually Uz in the percentage of rated voltage, that is, Uz =(Uz/U1n)*100%

When the transformer runs at full load, the short-circuit impedance has a certain influence on the output voltage of the secondary side. The short-circuit impedance is small, the voltage drop is small, the short-circuit impedance is large, the voltage drop is large. When the transformer load appears short circuit, the short circuit impedance is small, the short circuit current is large, the transformer bears the electric power is big. The short circuit impedance is large, the short circuit current is small, the transformer bears the electric power is small.

Above is the transformer short circuit impedance effect and the concept of the basic analysis for your reference, you can continue to promote the stability of the transformer and the safety of the operation, so that the transformer's many effects will play out, and is relatively safe!

That's all for the sharing, thanks for your reading, and we also supply high quality oil transformer for sale, if you have any demand for our products, just feel free to contact us.