user login

Standard climate air source swimming pool heat pump

1000.0 USD
Min. Order: 1 Set/Sets
Payment Terms: L/C, T/T, WU
Supply Ability: 2000
Place of Origin: Guangdong

Company Profile

Location: Zhongshan, Guangdong, China (Mainland)
Business Type: Manufacturer, Agent

Product Detail

Means of Transport: Ocean, Air, Land
Capacity Type: Heavy Duty
Category: Heat Pump
Certification: CE
Brand Name: LASWIM
Material: Galvanized steel
Type: Vertical air flow
Function: Water heating and cooling
Production Capacity: 2000
Packing: Wooden case or strong export carton
Delivery Date: 25 days after advance payment
Show

Product Description

Laswim swimming pool heat pumps are specifically designed to economically provide heating to high activity and larger pools such as those in camp sites, leisure parks, hotels etc. Heat pumps are recognised as the most sustainable way to dynamically heat swimming pool water and with a heat pump you will save both energy and operating costs. Laswim heat pumps are available for seasonal use during typical outdoor pool usage periods or for indoor pool, all year round enjoyment.

Features:  

1. Premium materials and components, providing great stability, high efficiency and long life time;

2. Easy for installation and can be installed outside or in a plant room.

3. Safe and reliable, the electricity does not heat the pool directly, it is completely separated from the water, greatly improving the safety of swimmers and employees.

4. High efficiency and energy saving. The unit requires only a small amount of electricity can be converted into 3-4 times of heat to the water, high energy conversion rate, significant savings in operating costs.

5. Anti-corrosion and durable, excellent anti-corrosion galvanized steel sheet panel and PVC + titanium heat exchanger, ensure the main components in contact with the swimming pool      can effectively resist the erosion of chloride ion in water.

6. Intelligent control, temperature control system of heat pump can accurately monitor the      water temperature, keep the water temperature close to the set temperature, to achieve the purpose of constant temperature. 

7. Multiple and careful protection to ensure safety and long life time.

    Applications

    · Indoor or outdoor pools

    · Water parks

    · Hotel pools

    · Holiday parks and campsites 

    Technical parameters:

    Technical parameters

    Model
      LAS70-KP

    Model
      LAS85-KP

    Model
      LAS100-KP

    Standard heating
      condition

    Heating
      capacity

    kW

    70

    85

    100

    COP

    4.6

    4.5

    4.6

    Low temperature
      heating condition

    Heating
      capacity

    kW

    52

    62

    75

    COP

    3.7

    3.7

    3.6

    Cooling condition

    Cooling
      capacity

    kW

    52

    62

    70

    EER

    3.2

    3.1

    3.2

    Power supply

    V/ph/Hz

    380V/3N~/50Hz

    Rated power input

    kW

    15.2

    18.9

    21.7

    Rated current

    A

    28.9

    35.9

    36.6

    Max. power input

    kW

    22

    27

    29.5

    Max. current

    A

    41.8

    51.3

    49.8

    Max. water intlet temperature

    40℃

    Applicable ambient temperature

    ﹣5℃~43℃

    Warter side heat exhanger

    PVC+Titanium

    Max. pressure

    MPa

    2.8

    Refrigerant type

    R407C / R410A

    Air volume at 30Pa

    m³/h

    19500

    19500

    19500

    Noise level

    dB(A)

    ≤70

    ≤70

    ≤70

    Water inlet/outlet size

    mm

    63

    63

    63

    Water flow rate

    m³/h

    20

    25

    30

    Water side pressure drop

    kPa

    51

    53

    55

    Net weight

    Kg

    560

    650

    750

    Dimension

    mm

    2250x1035x1200


Post Buying Request