Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | EXW |
Payment Terms: | T/T |
Supply Ability: | 10000 |
Place of Origin: | Guangdong |
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer, Distributor/Wholesaler |
Model No.: | CE-7002-100V200A |
---|---|
Means of Transport: | Ocean, Air, Land |
Certification: | CE |
Type: | Lithium |
Usage: | Car |
Brand Name: | Neware |
Current range: | 1~200A |
Voltage range: | 10~100V |
Charge Mode: | CCC, CVC, CC&CVC,CPC |
Discharge Mode: | CCD, CPD,CRD |
Data frequency: | 10Hz |
Min Pulse Width: | 100ms |
Production Capacity: | 10000 |
Packing: | wooden box |
Delivery Date: | 7 days after payment |
Neware
Since 1998, Neware has been committed to providing world-class testing solutions for the batteries and capacitors. We adopt SAP as our ERP system and comply with ISO9000 quality management standard. Our factory spans over 8,000 square meters in industrial park, Shenzhen office spans over 2,000 square meters, housing all R&D, Engineering, Sales and CRM personnel. To explore international market, we launched Hong Kong and France offices in 2011.
Product Series:
· BTS-4000 Battery Tester for Coin Cell Battery, Cylindrical Battery
· BTS-7000 Battery Tester for Pack Battery
· BTS-8000 Battery Tester for Power Battery
· BTS-9000 Battery Tester for Battery Material Research
BTS 7000 Introduction
Neware IGBT Series is designed for testing high power battery packs, and applied to electric vehicles, military technology, and stationary grid storage demand high-reliability and safe testing environments.
IGBT offers battery testing system for basic charge/discharge cycling, simulation application. It brings you higher energy efficiency, smaller space and much convenient to utilize the existing gauge integrated in BMS/BMU. It has an energy regenerative function to greatly reduce power consumption during discharge, and ensure a stable power grid without generating harmonic pollution on other devices.
Application:
Capacity Test
Charge (CCC, CVC, CCCVC, CPC)
Discharge (CCD,CPD,CRD)
Cycle Life Test
Formation & Grading
Over-charge, Over-discharge
Driving Simulation
Energy Saving
_Device Display_
_Accessories_
IGBT-100V200A Tester for Electric Vehicle Battery | |||
Project Index | Parameter Index | ||
Input Power | AC 380V ±10% / 50Hz | ||
resolution | AD:16bit;DA:16bit | ||
Output Power | 40KW | ||
Input Power | 44KW | ||
Voltage | Per Channel Control Voltage Range | 10V~100V | |
Minimum discharge voltage | 10V | ||
Accuracy | ± 0.1% of FS | ||
Stability | ± 0.1% of FS | ||
Current | Per Channel Current Range | 1A~200A | |
Constant current cut-off current | ± 0.1% of FS | ||
Accuracy | 0.4A | ||
Stability | ± 0.1% of FS | ||
Power | Per Channel Output Power | 20K | W |
Stability | ± 0.2% of FS | ||
Time | Current Response Time | ≤ 10ms (0-Full Range) | |
Step Time Range | ≤(365*24 )hour/step, Time Form Support 00:00:00(h,min:s,ms) | ||
Data Recording | Record Condition | Time△t:100ms | |
Voltage△U:0.2V | |||
Current△I:0.4A | |||
Record Frequency | 10Hz | ||
Charge | Charge Mode | Constant Current Charge,Constant Voltage Charge, Constant Current and Constant Voltage Charge,Constant Power Charge | |
End Condition | Voltage,Current,Relative Time,Capacity,-△V | ||
Discharge | Discharge Mode | Constant Current Discharge,Constant Power Discharge,Constant Resistance Discharge | |
End Condition | Voltage,Current,Relative Time,Capacity,-△V | ||
Pulse Test | Charge | Constant Current Charge,Constant Power Charge | |
Discharge | Constant Current Discharge,Constant Power Discharge | ||
Minimum Pulse Width | 500ms | ||
Pulse Number | 32 different pulse for a single step | ||
Charge And Discharge Switch | continuous switched for a single pulse step | ||
End Condition | Voltage,Relative Time |
Software Setting:
Using your computer to set customized testing steps after installing our professional software which can record the current, voltage, energy, time of your batteries. After testing, all data can be download into excel.
Testing Steps and Parameter Setting: | ||||
CCD (constant current discharge) | CCC (constant current charge) | CVC (Constant voltage Charge) | CVD (Constant voltage discharge) | Cycles
|
Capacity, voltage, time, current limit, Max Vi, Min Vi, Max Ti, Min Ti | -∆V, Capacity, voltage, time, current limit, Max Vi, Min Vi, Max Ti, Min Ti | Capacity, voltage limit, time, current, Max Vi, Min Vi, Max Ti, Min Ti | Capacity, voltage limit, time, current, Max Vi, Min Vi, Max Ti, Min Ti | Cycle start step, cycle times |
CPD | CPC | CRD | CCCVC | Rest |
Power, time, voltage | Power, time, voltage | Load, time, current | Capacity, time, cut-off current | Time limit |
Software Features:
1. Each channel available for dependent program testing, Step is continuable after Pause in any conditions (including blackout).
2. Host computer adaptable to all kinds of lower machine, with interactive interface, easy to operate.
3. Fast data acquisition, sensitive to the changing of current & voltage, (AD,16bit), dairy function available.
4. Powerful for data and chart processing, support four types of report with various form formats.
5. As an added bonus, professional tool software would be provided free of charge.
Customer Group:
Domestic: Tsinghua University, Peking University, Fudan University, Central South University, Zhejiang University, etc.
International: University of Waterloo, Stanford University, Mitsubishi, Philips, and Oxford University, the University of Sydney, etc.
Service:
Instant reply to customers needs within 24 hours.
Urgent need within 2 hours.
Confidentiality agreement to all related technical and business information.
Remote guidance on Phone/ the Internet.
Accuracy calibration
Resident technical engineer
Dust removing and maintenance
The price above is not the final price.
Pls contact me on Skype/Wechat( +8618102709482)