Min. Order: | 1 Piece/Pieces |
---|---|
Payment Terms: | T/T |
Place of Origin: | Hunan |
Location: | Changsha, Hunan, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Means of Transport: | Ocean, Air, Land |
---|
I. Introduction
SS-UV-300 flue gas analyzer (low emission monitoring) based on years of experience in research and development of flue gas analyzer, combined with the field practice of nearly ten thousand successful application cases. A number of techniques of the flue gas analyzer (standard form) are upgraded (many times return room to increase gas absorption optical path, and higher accuracy of spectrometer, convection heat transfer core module temperature control, etc.).
The analyzer is based on DOAS and chemometric algorithms (PLS), able to measure concentration of gas including SO2, NO2, NO, O2, NH3, Cl2, O3, H2S, CH3I, etc. It has features of high measure accuracy, outstanding reliability, fast response time and wide applicable scope. All indexes reach or exceed those of domestic & foreign similar products, and fully qualify measurement technology index of low emission monitoring occasions.
II. Application fields
It mainly used for industrial boilers, industrial furnaces emissions monitoring in power plant, iron & steel factory, cement plant and son.
III. Specifications
Model | Standard | Low Emission | Ultra-low Emission |
Range | 0-300-3000ppm | 0-100-300ppm | 0-20-100ppm |
Linearity | ≤±1.5%F.S. | ||
Repeatability | ≤±0.5%F.S. | ||
Zero Drift | ≤±2%F.S/7d | ||
Span Drift | ≤±2%F.S/7d | ||
Response time(T90) | ≤10S | ≤30S | ≤30S |
Working Temp | -10℃-+40℃ | ||
Preheating time | No preheating | Approx.10 min | |
Sample Gas Interface | Ø6 | ||
Sample Gas Flow | (0.5-2)L/min,Fluctuation<25% | ||
Sample Gas Pressure | The current encironmental pressure ±0.1 Bar | ||
Sample Temperature | 0℃-+50℃ | ||
Sample Gas Humidity | No condenstation (under sample temperature) | ||
4-20mA inpt interface | 3,configurable,100Ω load | ||
4-20mA Output Interface | 5,output can be configured ,maximum load capacity<800Ω | ||
Switch Input Interface | 6, configured | ||
Relay Output Interface | 14, output ca be configured,DC30V2A | ||
Communication Interface | 1*RS232,1*RS485(support the Modbus protocol) | ||
Installation | Installed in 19inch cabinet | ||
Supply | 220VAC±10% | ||
Power Consumption | About 100W | About 200W | |
Dimension | 132(H)*483(W)*378(D)mm | 177(H)*483(W)*412(D)mm | 177(H)*483(W)*434(D)mm |
Weight | About 10kgs | About 12kgs |
IV. Product feature
1. High measurement accuracy
2. The minimum detection limit of SO2 , NO2, NO can be 1mg/m3 (15m optical path)
3. Ultraviolet has no moisture absorption, undisturbed by moisture and dust.
4. No cross interference between the gas being measured (see table 1)
5. NO and NO2 can be measured at the same time, dispense with converter
6. High reliability
7. White cell + DOAS + PLS technology, small amount of zero drift and span drift
8. Modular design
9. No optical moving parts and no vibration influence
10. Strong gas cell, low cost
11. Spectrum automatic adjustment technology, long free maintenance cycle
12. Light source adopts the pulse source, the service life is 10 years